EMC-008 (Rev.0)
 
HEAD OFFICE 
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea  
  
(TEL: 
+82-31-746-8500, FAX: +82-31-746-8700
)
 
EMC Testing Dept : 
426-1 
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
 
ONETECH
Testing & Evaluation Lab. 
7. ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST 
The measurement of the Immunity Fast Transient/Burst was performed in a shield room. 
Test Location: Shielded Room (S-01) 
Date: January 08, 2004 
7.1 Operating environment 
Ambient temperature 
17 [°C] 
(15 – 35°C) 
Relative humidity 
38 [%] 
(25 – 75 %) 
Atmospheric pressure 
1004 [mbar] 
(860 – 1060 mbar) 
7.2 Test set-up 
The EUT and all local support equipment were placed a non-metallic support 0.8m above a reference ground plane (RGP) 
and was put into operation according to the specified operating mode. If the EUT has a non-detachable supply cable more 
than 1 m long, the excess length of this cable was gathered into a flat coil with a 0.4m diameter and situated at a distance of 
0.1m above the RGP. 
A photo of the test set-up is included in appendix IV 
7.3 Measurement uncertainty 
The uncertainty of the applied fast transients/burst is within the tolerance specified by the standard. 
7.4 Test equipment used 
 
Model Number 
Manufacturer 
Description 
Serial Number 
„ -  UCS 500 
EM Test 
Ultra Compact Generator 
UCS-500-0596-40 
„ -  AC2716 
EM Test 
Power Source 
96.30.1037 
„ -  N/A 
EM Test 
Capacitive Coupling Clamp  N/A 
All test equipment used is calibrated on a regular basis. 
 