Read JBL GTO 601.1 (serv.man12) EMC - CB Certificate online
Page 12 of 17
File No.: E042R-017
It should not be reproduced except in full, without the written approval of ONETECH.
EMC-008 (Rev.0)
HEAD OFFICE
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea
(TEL:
+82-31-746-8500, FAX: +82-31-746-8700
)
EMC Testing Dept :
426-1
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
ONETECH
Testing & Evaluation Lab.
7. ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
The measurement of the Immunity Fast Transient/Burst was performed in a shield room.
Test Location: Shielded Room (S-01)
Date: January 08, 2004
7.1 Operating environment
Ambient temperature
17 [°C]
(15 – 35°C)
Relative humidity
38 [%]
(25 – 75 %)
Atmospheric pressure
1004 [mbar]
(860 – 1060 mbar)
7.2 Test set-up
The EUT and all local support equipment were placed a non-metallic support 0.8m above a reference ground plane (RGP)
and was put into operation according to the specified operating mode. If the EUT has a non-detachable supply cable more
than 1 m long, the excess length of this cable was gathered into a flat coil with a 0.4m diameter and situated at a distance of
0.1m above the RGP.
A photo of the test set-up is included in appendix IV
7.3 Measurement uncertainty
The uncertainty of the applied fast transients/burst is within the tolerance specified by the standard.
7.4 Test equipment used
Model Number
Manufacturer
Description
Serial Number
- UCS 500
EM Test
Ultra Compact Generator
UCS-500-0596-40
- AC2716
EM Test
Power Source
96.30.1037
- N/A
EM Test
Capacitive Coupling Clamp N/A
All test equipment used is calibrated on a regular basis.
Click on the first or last page to see other GTO 601.1 (serv.man12) service manuals if exist.