5. ELECTROSTATIC DISCHARGE IMMUNITY TEST
The measurement of the Immunity Against Electrostatic Discharge was performed in a shield room.
Test Location: Shielded Room (S-01).
Date: January 08, 2004
5.1 Operating environment
Ambient temperature
16 [°C]
(15 – 35 °C)
Relative humidity
39 [%]
(30 – 60 %)
Atmospheric pressure
1004 [mbar]
(860 – 1060 mbar)
5.2 Test set-up
The EUT and all local support equipment were placed on non-metallic support 0.8m above a reference ground plane (RGP)
and were put into operation according to the specified operating mode.
A photo of the test set-up is included in appendix II.
5.3 Measurement uncertainty
The uncertainty of the applied electrostatic discharges is within the tolerance specified by the standard.
5.4 Test equipment used
Model Number
Manufacturer
Description
Serial Number
- ESS-630A
NOISE LABORATORY
ESD Simulator
A863019
- TC-815D(F)
NOISE LABORATORY
ESD Gun
H567773
All test equipment used is calibrated on a regular basis.