GTO 601.1 (serv.man12) - JBL Car Audio EMC - CB Certificate (repair manual). Page 19

Read JBL GTO 601.1 (serv.man12) EMC - CB Certificate online

 
Page 8 of 17 
 
 
File No.: E042R-017 
It should not be reproduced except in full, without the written approval of ONETECH. 
EMC-008 (Rev.0)
 
HEAD OFFICE 
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea  
  
(TEL: 
+82-31-746-8500, FAX: +82-31-746-8700
)
 
EMC Testing Dept : 
426-1 
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
 
ONETECH
Testing & Evaluation Lab. 
5. ELECTROSTATIC DISCHARGE IMMUNITY TEST 
The measurement of the Immunity Against Electrostatic Discharge was performed in a shield room. 
Test Location: Shielded Room (S-01). 
Date: January 08, 2004 
5.1 Operating environment 
Ambient temperature 
16 [°C] 
(15 – 35 °C) 
Relative humidity 
39 [%] 
(30 – 60 %) 
Atmospheric pressure 
1004 [mbar] 
(860 – 1060 mbar) 
5.2 Test set-up 
The EUT and all local support equipment were placed on non-metallic support 0.8m above a reference ground plane (RGP) 
and were put into operation according to the specified operating mode. 
A photo of the test set-up is included in appendix II. 
5.3 Measurement uncertainty 
The uncertainty of the applied electrostatic discharges is within the tolerance specified by the standard. 
5.4 Test equipment used 
 
Model Number 
Manufacturer 
Description 
Serial Number 
„ -  ESS-630A 
NOISE LABORATORY 
ESD Simulator 
A863019 
„ -  TC-815D(F) 
NOISE LABORATORY 
ESD Gun 
H567773 
All test equipment used is calibrated on a regular basis. 