GTO 601.1 (serv.man12) - JBL Car Audio EMC - CB Certificate (repair manual). Page 21

Read JBL GTO 601.1 (serv.man12) EMC - CB Certificate online

 
Page 10 of 17 
 
 
File No.: E042R-017 
It should not be reproduced except in full, without the written approval of ONETECH. 
EMC-008 (Rev.0)
 
HEAD OFFICE 
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea  
  
(TEL: 
+82-31-746-8500, FAX: +82-31-746-8700
)
 
EMC Testing Dept : 
426-1 
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
 
ONETECH
Testing & Evaluation Lab. 
6. RADIATED RF-ELECTROMAGNETIC FIELD IMMUNITY TEST 
The  measurement of the  Immunity Against Radiated RF-Electromagnetic Field was performed in an anechoic 
chamber. 
Test Location: Anechoic Chamber (S-02). 
Date: January 08, 2004 
6.1 Operating environment 
Ambient temperature 
16 [°C] 
Relative humidity 
38 [%]   
Atmospheric pressure 
1004 [mbar]   
6.2 Test set-up 
The EUT and all local support equipment were placed on a non-metallic support 0.8m above a reference ground plane 
(RGP) and were put into operation according to the specified operating mode. 
A photo of the test set-up is included in appendix III. 
6.3 Measurement uncertainty 
The measurement uncertainty is ±0.27V/m for 1V/m, ±0.71V/m for 3V/m and ±2.2V/m for 10V/m. 
Measurement uncertainty is calculated in accordance with WECC 19-1990. The measurement uncertainty is given with a 
confidence of 95%. The measurement uncertainty is calculated as the uncertainty of the electric field intensity detected by 
the probe(s). The uncertainty calculations exclude influence of phenomena like inhomogeneity of the electric field intensity 
6.4 Test equipment used 
 
Model Number 
Manufacturer 
Description 
Serial Number 
„ -  SMT02 
Rohde & Schwarz 
Signal Generator 
843351/002 
„ -  NRVD 
Rohde & Schwarz 
Power Meter 
843789/002 
„ -  SCIU 
Rohde & Schwarz 
System Control/Interface Unit 
338224/004 
„ -  DCU 
Rohde & Schwarz 
Directional Coupler Unit 
338333/001 
„ -  CS-LDE 
Rohde & Schwarz 
Line Distributor 
1028.3481.13 
„ -  DESKPRO 2000 
COMPAQ 
Main Computer 
8629HVS63023 
† -  500C100 
Amplifier Research 
Power Amplifier 
19540 
„ -  200W100M7A 
Amplifier Research 
Power Amplifier 
19406 
„ -  AT1080 
Amplifier Research 
Log Periodic Antenna 
17611 
† -  3109 
EMCO 
Biconical Antenna 
9606-3013 
„ -  FP4000 
Amplifier Research 
Isotropic Field Probe 
18825 
All test equipment used is calibrated on a regular basis. 