Read JBL GTO 601.1 (serv.man12) EMC - CB Certificate online
Page 11 of 17
File No.: E042R-017
It should not be reproduced except in full, without the written approval of ONETECH.
EMC-008 (Rev.0)
HEAD OFFICE
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea
(TEL:
+82-31-746-8500, FAX: +82-31-746-8700
)
EMC Testing Dept :
426-1
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
ONETECH
Testing & Evaluation Lab.
6.5 Test data
Test level
: 3 V/m (200Hz, Pulse ON/ OFF 50%)
Frequency range
: 895 MHz ~ 905 MHz
Frequency step
: 1 %
Dwell time at each frequency
: 3 s
Exposed side
: Front / Rear / Left / Right
Polarization of antenna
: Horizontal / Vertical
Distance of antenna – EUT
: 3 m
Required performance criterion
: A
EUT-position
: Table top
Test result
: Met criterion A
Monitoring of the EUT
: Observed the 100Hz sine wave to output terminal with oscilloscope.
The results of test are listed in below table.
Freq. Range
[MHz]
Ant.
Pol.
Exposed side
Pass/
Fail
Description
895 - 905
V
Front / Rear / Left / Right
Pass
There was no deviation from normal operation condition.
895 - 905
H
Front / Rear / Left / Right
Pass
There was no deviation from normal operation condition.
Remark: “H”: Horizontal, “V”: Vertical
Tested by: Eung-Chan, Kim / Test Engineer