Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
8.18 
Endurance test as required by 8.17  
Certified source used. 
N/A 
8.19 
Disconnection from the mains 
See below. 
8.19.1 
Disconnect device  
See Engineering 
Considerations
 
and 
Markings and Instructions. 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
 
N/A 
8.19.2 
Mains switch ON indication  
 
N/A 
8.20 
Switch not fitted in the mains cord  
 
N/A 
8.21 
Bridging components comply with clause 14  
 
N/A 
8.22 
Non-separable thin sheet material  
 
N/A 
 
Electric shock hazard under normal operating conditions 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
 
N/A 
9.1.1.1 
a) Open circuit voltages  
See appended table. 
 
b) Touch current measured from terminal devices 
using the network in annex D  ................................. : 
See appended table. 
 
c) Discharge not exceeding 45 µC  
 
 
d) Energy of discharge not exceeding 350 mJ  
 
9.1.1.2 
Test with test finger and test probe  
The test probe B cannot touch 
any hazardous live part. 
The test probes 18 and 19 of 
IEC 61032 cannot touch any 
hazardous live part. 
9.1.2 
No hazardous live shafts of knobs, handles or levers   Complied. 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
No opening on whole 
equipment. 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  .................. : 
For input 132Vdc:7Vdc after 
2s. 
For input 264Vac: 22Vdc after 
2s. 
 
If C is not greater than 0,1 µF no test needed  
 
N/A 
9.1.7 
Resistance to external forces 
 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
Applied to enclosure. 