Read JBL SUB 250P (serv.man2) EMC - CB Certificate online
Page 13 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
8.18
Endurance test as required by 8.17
Certified source used.
N/A
8.19
Disconnection from the mains
See below.
P
8.19.1
Disconnect device
See Engineering
Considerations
Considerations
and
Markings and Instructions.
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
N/A
8.21
Bridging components comply with clause 14
N/A
8.22
Non-separable thin sheet material
N/A
9
Electric shock hazard under normal operating conditions
P
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
N/A
9.1.1.1
a) Open circuit voltages
See appended table.
P
b) Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
See appended table.
P
c) Discharge not exceeding 45 µC
P
d) Energy of discharge not exceeding 350 mJ
P
9.1.1.2
Test with test finger and test probe
The test probe B cannot touch
any hazardous live part.
any hazardous live part.
The test probes 18 and 19 of
IEC 61032 cannot touch any
hazardous live part.
IEC 61032 cannot touch any
hazardous live part.
P
9.1.2
No hazardous live shafts of knobs, handles or levers Complied.
P
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No opening on whole
equipment.
equipment.
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s .................. :
of the mains plug; voltage (V) after 2 s .................. :
For input 132Vdc:7Vdc after
2s.
2s.
For input 264Vac: 22Vdc after
2s.
2s.
P
If C is not greater than 0,1 µF no test needed
N/A
9.1.7
Resistance to external forces
P
a) Test probe 11 of IEC 61032 for 10 s (50 N)
Applied to enclosure.
P