Read JBL SUB 250P (serv.man2) EMC - CB Certificate online
Page 12 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Reinforced insulation > 0,4 mm (mm) .................... :
- Transformer (CT1 and T1)
bobbin thickness is 0.8mm
min.
min.
- Plastic chassis thickness
2.5mm
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
See below.
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
See appended table 10.3.
P
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N/A
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
P
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
Double insulation complied
with 8.9 and 10.3.
with 8.9 and 10.3.
P
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
Double insulation complied
with 8.9 and 10.3.
with 8.9 and 10.3.
P
8.11
Detaching of wires
No detaching of wires.
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
No undue reduction of
creepages or clearance
distances.
creepages or clearance
distances.
P
Vibration test carried out ......................................... :
Yes
P
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
Complied.
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
No risk of mechanical damage
to the insulation of the wires.
to the insulation of the wires.
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
Triple insulated wires used in
T1. See appended table 14.
T1. See appended table 14.
P
Click on the first or last page to see other SUB 250P (serv.man2) service manuals if exist.