Read JBL SUB 250P (serv.man2) EMC - CB Certificate online
Page 15 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.7
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
See appended table.
P
12
Mechanical strength
P
12.1.1
Bump test where mass >7 kg
No damage.
P
12.1.2
Vibration test
No damage.
P
12.1.3
Impact hammer test
Test was made on every weak
point of the enclosure and all
protruded parts; No damage,
complied with 10.3.
point of the enclosure and all
protruded parts; No damage,
complied with 10.3.
P
Steel ball test
No damage, complied with
10.3.
10.3.
P
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg
N/A
12.1.5
Thermoplastic enclosures stress relief test
80°C applied. No damage.
P
12.2
Fixing of knobs, push buttons, keys and levers
N/A
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
N/A
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
Clearances and creepage distances
P
13.1
Clearances in accordance with 13.3
See appended table.
P
Creepage distances in accordance with 13.4
See appended table.
P
13.2
Determination of working voltage
For T1
P
Location
Vrms
Vpeak
(Input: 240V)
6 – 1
217
352
6 – 2
220
440
6 – 3
218
352
6 – 4
218
352
6 – 5
218
364
8 – 1
213
464
8 – 2
213
388
8 – 3
215
480
8 – 4
214
464
8 – 5
213
460
Click on the first or last page to see other SUB 250P (serv.man2) service manuals if exist.