Read JBL SUB 250P (serv.man2) EMC - CB Certificate online
Page 7 of 54
Report No.: 11034065 001
TRF No. IEC60065K
permitted by the manufacturer’s specification of: 35°C.
•
The product is intended to be used in environment of pollution degree 2.
•
The product is intended for use on the following power systems: TN.
•
The equipment disconnect device is considered to be: plug.
•
Following transformers are provided (See subclause 1.5.4): Transformer (T2, CT1, DT1 and T1) is an
isolating transformer.
isolating transformer.
•
Components bridging insulation other than functional:
Components
ID
Bridging location
Bridging insulation
Capacitor
CY1,
CY2,
CY3,
CY4
CY2,
CY3,
CY4
Primary-to-secondary
Double/Reinforced (see subclause
8.6)
8.6)
--
Primary-to-earth
Basic (see subclause 8.5)
CX1,
CX2
CX2
Across mains
conductors
conductors
--
Resistor
--
Primary-to-secondary
Double/Reinforced (see subclause
8.6)
8.6)
--
Primary-to-earth
Basic (see subclause 8.5)
R5, R8,
R5A,
R8A
R5A,
R8A
Across mains
conductors
conductors
--
VDR
--
Primary-to-earth
Basic
ZNR1
Across mains
conductors
conductors
--
•
Following solid insulation other than wiring insulation are provided (See subclause 8.8):
Type of Insulation
Type of solid insulation (distance through
insulation / thin sheet
Location
Layer or
thickness
Reinforced insulation
distance through insulation
Plastic
enclosure
2.5mm
•
Following devices were considered protective devices (See subclause 14.5): Fuse (F1).
Additional Information
•
The temperature measurements were carried out with the apparatus positioned in testing box in
accordance with subclause 4.1.4
accordance with subclause 4.1.4
•
The power supply unit used in the product is not a certified product. Hence, compliance has been
evaluated in this report.
evaluated in this report.
•
The equipment is for use in multimedia systems and was investigated additionally to IEC GUIDE
112.
112.
•
The Label in Copy of marking plate is a draft of an artwork pending approval by National Certification
Bodies and it shall not be affixed to products prior to such an approval.
Bodies and it shall not be affixed to products prior to such an approval.
•
The plug was investigated and found in compliance with applicable parts of corresponding plug
standard: EN 50075.
standard: EN 50075.
•
The connector part of the removable plug portion was investigated and found in compliance with
applicable parts of IEC 61984.
applicable parts of IEC 61984.
•
Some components are pre-certified, which have been evaluated according to the relevant
requirements of IEC 60065, are employed in this product. Their suitability of use has been checked
accordingly.
requirements of IEC 60065, are employed in this product. Their suitability of use has been checked
accordingly.
Markings and Instructions
•
The instructions for use provided information that stating the apparatus shall not be exposed to dripping