Report No.: 11034065 001 
 
TRF No. IEC60065K 
 
 
 
permitted by the manufacturer’s specification of: 35°C. 
• 
The product is intended to be used in environment of pollution degree 2. 
• 
The product is intended for use on the following power systems: TN. 
• 
The equipment disconnect device is considered to be: plug. 
• 
Following transformers are provided (See subclause 1.5.4): Transformer (T2, CT1, DT1 and T1) is an 
isolating transformer. 
• 
Components bridging insulation other than functional: 
Components 
ID 
Bridging location 
Bridging insulation 
Capacitor 
CY1, 
CY2, 
CY3, 
CY4 
Primary-to-secondary 
Double/Reinforced (see subclause 
8.6) 
-- 
Primary-to-earth 
Basic  (see subclause 8.5) 
CX1, 
CX2 
Across mains 
conductors 
-- 
Resistor  
-- 
Primary-to-secondary 
Double/Reinforced (see subclause 
8.6) 
-- 
Primary-to-earth 
Basic (see subclause 8.5) 
R5, R8, 
R5A, 
R8A 
Across mains 
conductors 
-- 
VDR  
-- 
Primary-to-earth 
Basic 
ZNR1 
Across mains 
conductors 
-- 
 
• 
Following solid insulation other than wiring insulation are provided (See subclause 8.8): 
Type of Insulation 
Type of solid insulation (distance through 
insulation / thin sheet 
Location 
Layer or 
thickness 
Reinforced insulation 
distance through insulation 
Plastic 
enclosure 
2.5mm 
• 
Following devices were considered protective devices (See subclause 14.5): Fuse (F1). 
Additional Information 
• 
The temperature measurements were carried out with the apparatus positioned in testing box in 
accordance with subclause 4.1.4 
• 
The power supply unit used in the product is not a certified product. Hence, compliance has been 
evaluated in this report. 
• 
The equipment is for use in multimedia systems and was investigated additionally to IEC GUIDE 
112. 
• 
The Label in Copy of marking plate is a draft of an artwork pending approval by National Certification 
Bodies and it shall not be affixed to products prior to such an approval. 
• 
The plug was investigated and found in compliance with applicable parts of corresponding plug 
standard:  EN 50075. 
• 
The connector part of the removable plug portion was investigated and found in compliance with 
applicable parts of IEC 61984. 
• 
Some components are pre-certified, which have been evaluated according to the relevant 
requirements of IEC 60065, are employed in this product.  Their suitability of use has been checked 
accordingly. 
Markings and Instructions 
• 
The instructions for use provided information that stating the apparatus shall not be exposed to dripping 
Page of 112