SUB 250P (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 99

Read JBL SUB 250P (serv.man2) EMC - CB Certificate online

 
Page 44 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
2111 
14.6.1 
Switches and relays comply with UL 1054, UL 
61058-1 or UL 508 
 
14.6.1 
Mains switch or relay are rated for the total rated 
current consumption of the apparatus 
 
N/A 
14.6.1 
Rating of a mains switch or relay in audio 
apparatus intended for commercial use 
 
N/A 
14.6.2, 
14.6.3,  
14.6.4 
deleted. 
 
N/A 
14.6.5 
A switch or relay that controls a mains socket-
outlet have a rating equal to the rated current 
consumption of the apparatus plus the current 
rating of the socket-outlet 
 
N/A 
14.6.6 
Mains switches comply with (a), (b) or (c). The 
contacts of a mains relay complies with (a), (b) or 
(d). A switch that controls a mains receptacle 
complies with (b) and a relay that controls a mains 
receptacle complies with (b) or (d) 
 
N/A 
14.6.6a 
Switch or relay contacts have an rms current rating 
equal to or greater than the peak inrush current of 
the apparatus divided by 1.414 
 
N/A 
14.6.6a 
Switch or relay contacts have an rms current rating 
equal to or greater than the peak inrush current of 
the apparatus divided by 10, when: 
- the rms current during normal operation 
controlled by the switch is less than or equal to ½ 
the rms rating of the switch, and 
- the switch has double or multiple poles 
controlling the mains current, either in series or 
switching each mains line 
 
N/A 
14.6.6b 
Switch or relay is TV rated 
 
N/A 
14.6.6c 
Switch is located on the back of apparatus and is 
not operable from a remote control 
 
N/A 
14.6.6d 
Relay is to be subjected to the Relay endurance 
test 
 
N/A 
14.6.6.1 
Peak inrush current test 
 
N/A 
14.6.6.2 
Relay endurance test 
 
N/A 
14.6.7 
Double pole switch controlling a.c. and d.c. circuits   
N/A 
14.7 
The jointed test finger (figure 18) is used to 
determine accessibility and operation of the 
interlock 
 
N/A 
14.10.1 
 
N/A 
Page of 112
Display