Read JBL SUB 250P (serv.man2) EMC - CB Certificate online
Page 43 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
14.1
Component power supplies and their resistors
complying with UL 1310, UL 1950 Third Edition,
UL 60950, or UL 60950-1 are considered to fulfil
the clause
complying with UL 1310, UL 1950 Third Edition,
UL 60950, or UL 60950-1 are considered to fulfil
the clause
N/A
14.2
Component power supplies and their resistors
complying with UL 1310, UL 1950 Third Edition,
UL 60950, or UL 60950-1 are considered to fulfil
the clause
complying with UL 1310, UL 1950 Third Edition,
UL 60950, or UL 60950-1 are considered to fulfil
the clause
N/A
14.2.1
As an alternative, a component such as a
capacitor, a combination capacitor and resistor, or
a suppressor may comply with UL 1414.
capacitor, a combination capacitor and resistor, or
a suppressor may comply with UL 1414.
P
14.2.2
As an alternative, a capacitor, a combination
capacitor and resistor, or a varistor, or a
suppressor may comply with UL 1414.
capacitor and resistor, or a varistor, or a
suppressor may comply with UL 1414.
P
14.2.4
Components subjected to the requirements in
14.2.1 and 14.2.2 also comply with UL 1414
enclosure requirements
14.2.1 and 14.2.2 also comply with UL 1414
enclosure requirements
N/A
14.3
Component power supplies and their inductors
and windings complying with UL 1310, UL 1950
Third Edition, UL 60950, or UL 60950-1 are
considered to fulfill the clause
and windings complying with UL 1310, UL 1950
Third Edition, UL 60950, or UL 60950-1 are
considered to fulfill the clause
N/A
14.3.2
Planar transformers comply with the requirements
for multilayer printed boards
for multilayer printed boards
N/A
14.4
Planar transformers comply with the requirements
for multilayer printed boards
for multilayer printed boards
N/A
14.4.1
High voltage arcing test replaces the High voltage
transformers and multipliers test
transformers and multipliers test
N/A
14.4.2
Deleted
N/A
14.4.3
High voltage component part flame test
N/A
14.4.4
High voltage isolating component test
N/A
14.5.1.1
Thermal cut-outs comply with UL 873 or UL
60730-2-9
60730-2-9
N/A
14.5.1.2
Thermal links comply with UL 60691
N/A
14.5.1.3
Deleted
N/A
14.5.2.1
Fuse links comply with UL 248-14
P
14.5.2.2
Reference to IEC 60127 is deleted
N/A
14.5.2.2
Pre-arcing time/current characteristic and breaking
capacity marking requirements are deleted
capacity marking requirements are deleted
N/A
14.5.3
As an alternative, a PTC thermistor may comply
with requirements of UL 1434
with requirements of UL 1434
N/A
14.5.4
Reference to fuse-links is deleted
N/A
14.5.3A
Other protective devices directly connected to the
mains have adequate breaking capacity and
comply with UL 873, UL 1416, UL 1417 or UL
mains have adequate breaking capacity and
comply with UL 873, UL 1416, UL 1417 or UL
N/A