Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
14.1 
Component power supplies and their resistors 
complying with UL 1310, UL 1950 Third Edition, 
UL 60950, or UL 60950-1 are considered to fulfil 
the clause 
 
N/A 
14.2 
Component power supplies and their resistors 
complying with UL 1310, UL 1950 Third Edition, 
UL 60950, or UL 60950-1 are considered to fulfil 
the clause 
 
N/A 
14.2.1 
As an alternative, a component such as a 
capacitor, a combination capacitor and resistor, or 
a suppressor may comply with UL 1414. 
 
14.2.2 
As an alternative, a capacitor, a combination 
capacitor and resistor, or a varistor, or a 
suppressor may comply with UL 1414. 
 
14.2.4 
Components subjected to the requirements in 
14.2.1 and 14.2.2 also comply with UL 1414 
enclosure requirements 
 
N/A 
14.3 
Component power supplies and their inductors 
and windings complying with UL 1310, UL 1950 
Third Edition, UL 60950, or UL 60950-1 are 
considered to fulfill the clause 
 
N/A 
14.3.2 
Planar transformers comply with the requirements 
for multilayer printed boards 
 
N/A 
14.4 
Planar transformers comply with the requirements 
for multilayer printed boards 
 
N/A 
14.4.1 
High voltage arcing test replaces the High voltage 
transformers and multipliers test 
 
N/A 
14.4.2 
Deleted 
 
N/A 
14.4.3 
High voltage component part flame test 
 
N/A 
14.4.4 
High voltage isolating component test 
 
N/A 
14.5.1.1 
Thermal cut-outs comply with UL 873 or UL 
60730-2-9 
 
N/A 
14.5.1.2 
Thermal links comply with UL 60691 
 
N/A 
14.5.1.3 
Deleted 
 
N/A 
14.5.2.1 
Fuse links comply with UL 248-14 
 
14.5.2.2 
Reference to IEC 60127 is deleted 
 
N/A 
14.5.2.2 
Pre-arcing time/current characteristic and breaking 
capacity marking requirements are deleted 
 
N/A 
14.5.3  
As an alternative, a PTC thermistor may comply 
with requirements of UL 1434 
 
N/A 
14.5.4 
Reference to fuse-links is deleted 
 
N/A 
14.5.3A 
Other protective devices directly connected to the 
mains have adequate breaking capacity and 
comply with UL 873, UL 1416, UL 1417 or UL 
 
N/A 
Page of 112