Read JBL ON TIME MICRO (serv.man2) EMC - CB Certificate online
- Page 22 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
20
RESISTANCE TO FIRE ( The approved Class II switching power supply
be used.)
be used.)
P
20.1
Electrical components and mechanical parts
No exception of condition a) or b), it shall comply with the requirements of 20.1.1,
20.1.2, 20.1.3 and 20.1.4.
20.1.2, 20.1.3 and 20.1.4.
N
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60 707 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60 707 with
openings not exceeding 1 mm in width
The approved Class II
switching power supply be
used.
switching power supply be
used.
N
b) Exemption for small components as defined in
20.1
20.1
PCB: V-0
N
20.1.1 Electrical
components
meet the requirements of
clause 14 or 20.1.4
N
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
N
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC 60 707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC 60 707, unless used in a fire
enclosure
N
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >
400 V (peak) a.c. or d.c. meets F-0 to IEC 60 707
available power exceeds 15 W at a voltage >
400 V (peak) a.c. or d.c. meets F-0 to IEC 60 707
N
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
N
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N
20.2 Fire
enclosure
N
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
No such high voltage.
N
20.2.2
No internal fire enclosure.
N