ON STAGEII (serv.man6) - JBL Audio EMC - CB Certificate (repair manual). Page 43

Read JBL ON STAGEII (serv.man6) EMC - CB Certificate online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
43 of 72 
 
4.2.  Radiated Emissions Test Data 
 
 
 
 
 
 
San Diego Headquarters:
11696 Sorrento Valley Rd.
San Diego, CA 92121
Tel:  (858) 755-5525
NEMKO USA, Inc.
Fax: (858) 452-1810
Radiated Emissions Data
Complete
X
Job # :
25-1114-HAR
Test # :
Preliminary
Page
1
of
1
Client Name :
Harman Multimedia
EUT Name :
I-Pod Cradle
EUT Model # :
JBL OnStage UD Computer System
EUT Part # :
EUT Serial # :
EUT Config. :
with Leader Power Supply
Specification :
EN55022: 1998, Class B
   Reference :
Rod. Ant. #:
NA
Temp. (deg. C) :
19
Date : 1/3/2005
Bicon Ant.#:
114
Humidity (%) :
50
Time :
Log Ant.#:
111
EUT Voltage :
50Hz
Staff : RR
DRG Ant. #
NA
EUT Frequency : 230VAC
Photo ID:
Dipole Ant.#:
NA
Phase:
1
Peak Bandwidth: 100 kHz
Cable#:
Soats2
Location:
soats
Video Bandwidth 100 kHz
Preamp#:
826
Distance:
10m
Spec An.#:
899
QP #:
899
PreSelect#:
NA
Meas.
Ant.
Atten.
Meter
Antenna
Path
RF
Corrected
Spec.
CR/SL
Pass
Freq.
Pol.
Reading
Factor
Loss
Gain
Reading
limit
Diff.
Fail
(MHz)
(H/V)
(dB)
(dBuV)
(dB)
(dB)
(dB)
(dBuV/m)
(dBuV/m)
(dB)
Unc.
Comment
43.9
V
0
43
11.1
1.3
32.6
22.8
30.0
-7.2
Pass
108.84
V
0
44
13.1
1.8
32.4
26.5
30.0
-3.5
Pass
134.9
V
0
42
11.7
1.8
32.6
22.9
30.0
-7.1
Pass
324
V
0
33.2
14.5
1.8
32.9
16.6
37.0
-20.4
Pass
383.98
V
0
34.4
14.9
1.8
32.9
18.2
37.0
-18.8
Pass
671.94
V
0
31
20.3
2.9
32.6
21.6
37.0
-15.4
Pass
Page of 72
Display

Click on the first or last page to see other ON STAGEII (serv.man6) service manuals if exist.