IEC 60950 3rd Ed., 1999.
- Page 4 of 5 -
Order No. 46974
Clause
Requirement - Test
Result - Remark
Ver-
dict
5.1.6
Replacement:
Replace Table 5A.
Replace Table 5A.
Class III equipment.
N/A
5.3.8.2
Replacement:
Replace 3rd Item as follows.
Replace 3rd Item as follows.
- BASIC INSULATION between the PRIMARY
CIRCUIT and accessible conductive parts of CLASS I
or 0I EQUIPMENT;
CIRCUIT and accessible conductive parts of CLASS I
or 0I EQUIPMENT;
Class III equipment.
N/A
Annex A
Addition:
Add the subclause A.101 with the title “Flammability
tests for classifying materials VTM” and the following:
Add the subclause A.101 with the title “Flammability
tests for classifying materials VTM” and the following:
Thin sheet materials shall comply with ISO 9773.
Considered. N/A
Annex G
Addition:
Add the following to the Note for Table G.1.
Add the following to the Note for Table G.1.
2. In Japan, MAINS TRANSIENT VOLTAGE for
equipment with a Nominal AC MAINS SUPPLY
VOLTAGE of 100V is to be decided based on the
column where Nominal AC MAINS SUPPLY
VOLTAGE in Table G.1 is 150V.
equipment with a Nominal AC MAINS SUPPLY
VOLTAGE of 100V is to be decided based on the
column where Nominal AC MAINS SUPPLY
VOLTAGE in Table G.1 is 150V.
Not used.
N/A
Annex P
Addition:
Add “IEC 61965:2000, Mechanical Safety for Cathode
Ray Tubes”.
Add “IEC 61965:2000, Mechanical Safety for Cathode
Ray Tubes”.
Considered N/A
Annex U
Replacement:
Replace 2nd paragraph.
Replace 2nd paragraph.
This annex covers to round winding wires having
diameters between 0.05 mm and 5.00 mm.
diameters between 0.05 mm and 5.00 mm.
No TIW used.
N/A
U.2.1
Replacement:
Electric strength
The test sample is prepared according to IEC 60851-
5:1997, 4.4.1 (for a twisted pair). The sample is then
subjected to the test of 5.2.2 of this standard, with a
test voltage not less than twice the appropriate voltage
in table 5B (see 5.2.2) of this standard. However, the
minimum values shall be as follows:
Electric strength
The test sample is prepared according to IEC 60851-
5:1997, 4.4.1 (for a twisted pair). The sample is then
subjected to the test of 5.2.2 of this standard, with a
test voltage not less than twice the appropriate voltage
in table 5B (see 5.2.2) of this standard. However, the
minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 3000 V, or;
INSULATION, 3000 V, or;
- for REINFORCED INSULATION, 6000 V.
No TIW used.
N/A