Read JBL ON STAGEII (serv.man18) EMC - CB Certificate online
IEC 60950 3rd Ed., 1999.
- Page 5 of 5 -
Order No. 46974
Clause
Requirement - Test
Result - Remark
Ver-
dict
U.2.2
Replacement:
Flexibility and adherence
Flexibility and adherence
Test 8 of IEC 60851-3:1996, 5.1.1, using the mandrel
diameters of table U.1. The test sample is then
examined in accordance with IEC 60851-3:1996,
5.1.1.4, followed by the test of 5.2.2 of this standard
except applying the test voltage between the wire and
the mandrel. A test voltage shall not be less than twice
the appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shall be as
follows:
diameters of table U.1. The test sample is then
examined in accordance with IEC 60851-3:1996,
5.1.1.4, followed by the test of 5.2.2 of this standard
except applying the test voltage between the wire and
the mandrel. A test voltage shall not be less than twice
the appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shall be as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
No TIW used.
N/A
Table U.1
Replacement:
Mandrel diameter
Mandrel diameter
The tension to be applied to the wire during winding on
the mandrel is calculated from the wire diameter to be
equivalent to 118 Mpa ± 10 % (118 N/mm2 ± 10 %).
No TIW used.
N/A
Click on the first or last page to see other ON STAGEII (serv.man18) service manuals if exist.