Read JBL ON STAGEII (serv.man18) EMC - CB Certificate online
IEC 60950 3rd Ed., 1999.
- Page 3 of 5 -
Order No. 46974
Clause
Requirement - Test
Result - Remark
Ver-
dict
2.6.101
Addition:
Earthing of CLASS 0I EQUIPMENT
Earthing of CLASS 0I EQUIPMENT
Plugs with a lead wire for earthing shall not be used for
equipment having a rated voltage exceeding 150V.
equipment having a rated voltage exceeding 150V.
For plugs with a lead wire for earthing, the lead wire
shall not be earthed by a clip.
shall not be earthed by a clip.
CLASS 0I EQUIPMENT shall be provided with an
earthing terminal or lead wire for earthing in the
external where easily visible.
earthing terminal or lead wire for earthing in the
external where easily visible.
Class III equipment.
N/A
3.2.5
Delete 1) in Table 3B.
Considered.
—
4.2.8
Addition:
Add the following informative remark after the last
sentence.
Add the following informative remark after the last
sentence.
Remark - IEC 61965 is also applicable instead of IEC
60065.
60065.
Considered. —
4.5.1
Addition:
Add the following to suffix 5) as specified in
“Conditions applicable to Table 4A, Parts 1 and 2”.
Add the following to suffix 5) as specified in
“Conditions applicable to Table 4A, Parts 1 and 2”.
With regard to Table 4A, insulating materials
complying with Japanese requirements (refer to
Japanese differences for the current IEC 60335-1 (3rd
Edition) in CB Bulletin 101B) are also acceptable.
complying with Japanese requirements (refer to
Japanese differences for the current IEC 60335-1 (3rd
Edition) in CB Bulletin 101B) are also acceptable.
Add a suffix 7) in “Conditions applicable to Table 4A,
Parts 1 and 2”.
Parts 1 and 2”.
In the right column of Table 4A, Part 1, add suffix 7) to
“50” (K), corresponding to “- without T – marking” in the
left column so as to become “50 7)”.
“50” (K), corresponding to “- without T – marking” in the
left column so as to become “50 7)”.
Add 7) to Table 4A, Part 2 as follows.
7) This value shall apply only to wiring or cords
complying with relevant IEC standards. Others shall
comply with Japanese requirements (refer to Japanese
differences for the current IEC 60335-1 (3rd Edition) in
CB Bulletin 101B).
complying with relevant IEC standards. Others shall
comply with Japanese requirements (refer to Japanese
differences for the current IEC 60335-1 (3rd Edition) in
CB Bulletin 101B).
Considered. N/A
4.7.3.2
Addition:
Add the following in 7th paragraph.
Add the following in 7th paragraph.
- for thin materials, e.g., flexible printed boards, etc.,
used inside equipment, be of FLAMMABILITY CLASS
VTM-2 or better.
used inside equipment, be of FLAMMABILITY CLASS
VTM-2 or better.
Considered. N/A
Click on the first or last page to see other ON STAGEII (serv.man18) service manuals if exist.