ON STAGEII (serv.man18) - JBL Audio EMC - CB Certificate (repair manual). Page 68

Read JBL ON STAGEII (serv.man18) EMC - CB Certificate online

IEC 60950 3rd Ed., 1999. 
- Page 3 of 5 - 
 
 
 
Order No.  46974 
 
 
Clause 
Requirement - Test 
Result - Remark 
Ver-
dict 
2.6.101 
Addition: 
Earthing of CLASS 0I EQUIPMENT 
Plugs with a lead wire for earthing shall not be used for 
equipment having a rated voltage exceeding 150V. 
For plugs with a lead wire for earthing, the lead wire 
shall not be earthed by a clip. 
CLASS 0I EQUIPMENT shall be provided with an 
earthing terminal or lead wire for earthing in the 
external where easily visible. 
Class III equipment. 
N/A
3.2.5 
Delete 1) in Table 3B. 
Considered. 
— 
4.2.8 
Addition: 
Add the following informative remark after the last 
sentence. 
Remark - IEC 61965 is also applicable instead of IEC 
60065. 
Considered. — 
4.5.1 
Addition: 
Add the following to suffix 5) as specified in 
“Conditions applicable to Table 4A, Parts 1 and 2”. 
With regard to Table 4A, insulating materials 
complying with Japanese requirements (refer to 
Japanese differences for the current IEC 60335-1 (3rd 
Edition) in CB Bulletin 101B) are also acceptable. 
Add a suffix 7) in “Conditions applicable to Table 4A, 
Parts 1 and 2”. 
In the right column of Table 4A, Part 1, add suffix 7) to 
“50” (K), corresponding to “- without T – marking” in the 
left column so as to become “50 7)”. 
Add 7) to Table 4A, Part 2 as follows. 
7) This value shall apply only to wiring or cords 
complying with relevant IEC standards. Others shall 
comply with Japanese requirements (refer to Japanese 
differences for the current IEC 60335-1 (3rd Edition) in 
CB Bulletin 101B). 
Considered. N/A
4.7.3.2 
Addition: 
Add the following in 7th paragraph. 
- for thin materials, e.g., flexible printed boards, etc., 
used inside equipment, be of FLAMMABILITY CLASS 
VTM-2 or better. 
Considered. N/A
Page of 77