ON STAGE III IIIP (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 66

Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online

 
 
<12014238 001 > 
 
 
Page 65 of 77 
 
BS 1363 (Partial) 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
 
12 
Construction 
12.1 
Disposition of the pins is same as fig. 4 
 
12.2 
Plugs shall comply with fig. 4 
 
 
Disposition of pins 
 
   
 
Between E and left plane 
max.  25.37 mm 
24.30  mm 
 
Between E and right plane 
max.  25.37 mm 
24.32  mm 
 
Between E and L 
11.05~11.18mm 
11.08  mm 
 
Between E and N 
11.05~11.18mm 
11.08  mm 
 
Between L or N and top plane 
max.  34.6mm 
27.74  mm 
 
Between E and L, N 
22.10~22.36mm 
22.30  mm 
 
Radius of top right corner 
min. 15mm 
15.50  mm 
 
Radius of top left corner 
min. 15mm 
         
15.50  mm 
 
Shape of earth pin 
 
   
 
 
Length  
22.23~23.23mm 
22.60  mm 
 
Width 
7.80~8.05mm 
8.00  mm 
 
Thickness 
3.90~4.05mm 
4.00  mm 
 
Length of chamfer 
1.35~1.85mm 
1.68  mm 
 
Angle of chamfer 
58°~62° 
59 
°
 
 
Shape of L and N pin 
 
   
 
Length  
17.2~18.2mm 
17.80  mm 
 
Width 
6.22~6.48mm 
6.30  mm 
 
Thickness 
3.90~4.05mm 
4.00  mm 
 
Length of insulating material 
max.  9.5mm 
9.36  mm 
 
Length of conductive material  
max. 9.2mm 
8.44  mm 
 
Length of chamfer 
1.35~1.85mm 
1.56  mm 
 
Angle of chamfer 
58°~62° 
59 
°
 
 
Maintenance of these dimensions not rely on the 
terminal screws 
 
 
The plug portion should enter the gauge fully with 
a force less than 10N was applied to the centre of 
the sample at right angle. 
Complied, sample was entered 
into the gauge fully with a force 
of 10N.   
 
 
 
 
Page of 78
Display