Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online
<12014238 001 >
Page 65 of 77
BS 1363 (Partial)
Clause
Requirement − Test
Result – Remark
Verdict
12
Construction
P
12.1
Disposition of the pins is same as fig. 4
P
12.2
Plugs shall comply with fig. 4
P
Disposition of pins
P
Between E and left plane
max. 25.37 mm
24.30 mm
P
Between E and right plane
max. 25.37 mm
24.32 mm
P
Between E and L
11.05~11.18mm
11.08 mm
P
Between E and N
11.05~11.18mm
11.08 mm
P
Between L or N and top plane
max. 34.6mm
27.74 mm
P
Between E and L, N
22.10~22.36mm
22.30 mm
P
Radius of top right corner
min. 15mm
15.50 mm
P
Radius of top left corner
min. 15mm
15.50 mm
P
Shape of earth pin
Length
22.23~23.23mm
22.60 mm
P
Width
7.80~8.05mm
8.00 mm
P
Thickness
3.90~4.05mm
4.00 mm
P
Length of chamfer
1.35~1.85mm
1.68 mm
P
Angle of chamfer
58°~62°
59
°
P
Shape of L and N pin
P
Length
17.2~18.2mm
17.80 mm
P
Width
6.22~6.48mm
6.30 mm
P
Thickness
3.90~4.05mm
4.00 mm
P
Length of insulating material
max. 9.5mm
9.36 mm
P
Length of conductive material
max. 9.2mm
8.44 mm
P
Length of chamfer
1.35~1.85mm
1.56 mm
P
Angle of chamfer
58°~62°
59
°
P
Maintenance of these dimensions not rely on the
terminal screws
terminal screws
P
The plug portion should enter the gauge fully with
a force less than 10N was applied to the centre of
the sample at right angle.
a force less than 10N was applied to the centre of
the sample at right angle.
Complied, sample was entered
into the gauge fully with a force
of 10N.
into the gauge fully with a force
of 10N.
P
Click on the first or last page to see other ON STAGE III IIIP (serv.man2) service manuals if exist.