ON STAGE III IIIP (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 46

Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online

 
 
<12014238 001 > 
 
 
Page 45 of 77 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
Note(s): 
Functional insulation shorted, see sub-clause 5.3.4. 
 
2.10.5 
TABLE: distance through insulation measurements 
Distance through insulation di at/of: 
U r.m.s. 
(V) 
Test voltage 
(V) 
Required di 
(mm) 
di 
(mm) 
Optocoupler (reinforced insulation) 
250 
3000 
0.4 
1)
 
Enclosure material (reinforced insulation) 
250 
3000 
0.4 
2.0 
Note(s): 
Further details are provided in table 1.5.1. 
Test voltages are a.c. 
 
4.5.1 
TABLE: temperature rise measurements 
 
test voltage (V) ..................................................... :  a: 264 V, 50 Hz 
b: 90 V, 60 Hz 
 
 
t1 (°C)  .................................................................. :  -- 
 
 
t2 (°C)  .................................................................. :  -- 
 
Rise ∆T of part/at: 
T (°C) 
allowed T
max
 (°C) 
Test voltage: 
(a) 
(b) 
-- 
Model DSA-20R-12 FEU 150204 
Plug portion 
48.2 
50.6 
-- 
T1 winding 
83.5 
82.8 
110 
T1 core 
77.7 
76.9 
110 
Linear Filter LF1 winding 
64.3 
80.3 
130 
PCB under Q1 
82.0 
82.8 
130 
PCB under D9 
79.8 
79.4 
130 
Electrolytic Capacitor C2 
71.2 
79.0 
105 
Opto-coupler U1 
75.6 
72.5 
100 
Primary lead wire 
58.3 
65.6 
80 
Output cord  
58.5 
58.2 
80 
Enclosure (inside) 
60.2 
60.9 
-- 
Enclosure (outside) 
46.2 
46.4 
95 
Ambient  
40.0 
40.0 
-- 
Model DSA-20R-12 FEU 102204 
Plug portion 
52.3 
53.0 
-- 
T1 winding 
80.9 
81.9 
110 
T1 core 
83.4 
83.8 
110 
Page of 78