ON STAGE III IIIP (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 45

Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online

 
 
<12014238 001 > 
 
 
Page 44 of 77 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
2.10.2 
Table: working voltage measurement 
Location 
RMS voltage (V) 
Peak voltage (V)  Comments  
Model DSA-20R-12 FEU 150204 
T1 pin 1-8 
196 
360 
 
T1 pin 2-8 
280 
548 
Highest working voltage 
T1 pin 3-8 
205 
364 
 
T1 pin 4-8 
206 
388 
 
T1 pin 5-8 
210 
420 
 
T1 pin 1-10 
195 
380 
 
T1 pin 2-10 
264 
540 
 
T1 pin 3-10 
207 
384 
 
T1 pin 4-10 
210 
404 
 
T1 pin 5-10 
207 
390 
 
Note(s): 
Test voltage: 
240 V 
Test frequency:  60 Hz 
 
2.10.3 and 
2.10.4 
TABLE: clearance and creepage distance measurements 
Clearance cl and creepage 
distance dcr at/of: 
Up 
(V) 
U r.m.s. 
(V) 
Required 
cl (mm) 
cl 
(mm) 
Required 
dcr (mm) 
dcr 
(mm) 
Unit: 
primary components 
(with 10N) → secondary 
components (with 10N) 
548 
280 
4.4 
7.8 
6.0 
7.8 
Unit: 
primary components 
(with 10N) → core of T1 (with 
10N) 
548 
280 
2.2 
3.7 
3.0 
3.7 
Unit: 
core of T1 (with 10N) → 
secondary components (with 
10N) 
548 
280 
2.2 
3.7 
3.0 
3.7 
PCB:  primary → secondary 
traces under transformer 
548 
280 
4.4 
7.5 
6.0 
7.5 
PCB:  primary → secondary 
traces under U2 
548 
280 
4.4 
6.9 
6.0 
6.9 
Unit: 
primary components  → 
accessible part (outside 
enclosure) 
548 
280 
4.4 
6.5 
6.0 
6.5 
L, N before fuse 
420 
250 
1.5 
3.1 
2.5 
3.1 
Two pins of current fuse 
420 
250 
1.5 
2.9 
2.5 
2.9 
Page of 78
Display