Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online
<12014238 001 >
Page 42 of 77
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
Note(s): --
2.2.2
TABLE: Hazardous voltage measurement
P
max. Voltage
Transformer
Location
V peak
V d.c.
Voltage Limitation
Component
Component
Model DSA-20R-12 FEU 150204
T1
8-10
34.8
--
D9
Output
--
14.9
Note(s):
Test voltage:240 V
Test frequency: 60 Hz
The limits of SELV were not exceeded between any two points of the secondary circuit.
2.2.3
TABLE: SEL voltage measurement
P
Location
Voltage measured (V)
Comments
Model DSA-20R-12 FEU 150204
Output
0
Short-circuit D9, circuit protected immediately.
Note(s): --
2.4.2
TABLE: limited current circuit measurement
N/A
Location
Voltage
(V)
Current
(mA)
Freq.
(kHz)
(kHz)
Limit
(mA)
Comments
Note(s):
Test voltage:
--
Test frequency: --
2.5
TABLE: limited power source measurement
P
Limits
Measured
Verdict
Model DSA-20R-12 FEU 150204
Uoc = 14.9 V (measured under no load conditions)
According to Table 2B (normal condition)
current (in A)
≤8
2.52
P
apparent power (in VA)
≤5*Uoc= 74.5
26.2
P
According to Table 2B (Opto-coupler primary open-circuited)