ON STAGE III IIIP (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 43

Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online

 
 
<12014238 001 > 
 
 
Page 42 of 77 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
 
 
 
 
Note(s): -- 
 
2.2.2 
TABLE: Hazardous voltage measurement 
max. Voltage 
Transformer  
Location 
V peak 
V d.c. 
Voltage Limitation 
Component 
Model DSA-20R-12 FEU 150204 
T1 
8-10 
34.8 
-- 
D9 
 
Output  
-- 
14.9 
 
Note(s): 
Test voltage:240 V 
Test frequency: 60 Hz 
The limits of SELV were not exceeded between any two points of the secondary circuit. 
 
2.2.3 
TABLE: SEL voltage measurement 
Location 
Voltage measured (V) 
Comments 
Model DSA-20R-12 FEU 150204 
Output 
Short-circuit D9, circuit protected immediately. 
Note(s): -- 
 
2.4.2 
TABLE: limited current circuit measurement 
N/A 
Location 
Voltage 
(V) 
Current 
(mA) 
Freq. 
(kHz) 
Limit 
(mA) 
Comments 
 
 
 
 
 
 
 
Note(s):  
Test voltage: 
-- 
Test frequency:  -- 
 
2.5 
TABLE: limited power source measurement 
 
Limits 
Measured 
Verdict 
Model DSA-20R-12 FEU 150204 
Uoc = 14.9 V (measured under no load conditions) 
According to Table 2B (normal condition) 
current (in A) 
≤8 
2.52 
apparent power (in VA) 
≤5*Uoc= 74.5 
26.2 
According to Table 2B (Opto-coupler primary open-circuited) 
Page of 78
Display