ON STAGE III IIIP (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 42

Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online

 
 
<12014238 001 > 
 
 
Page 41 of 77 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
F1 
-- 
264 
22.2 
218 
218 
Rated load at 50 Hz 
F1 
-- 
264 
22.2 
207 
207 
Rated load at 60 Hz 
Model DSA-20R-12 FEU 102204 
F1 
-- 
90 
25.3 
476 
476 
Rated load at 50 Hz 
F1 
-- 
90 
25.3 
484 
484 
Rated load at 60 Hz 
F1 
700 
100 
24.9 
417 
417 
Rated load at 50 Hz 
F1 
700 
100 
25.0 
447 
447 
Rated load at 60 Hz 
F1 
700 
240 
24.6 
246 
246 
Rated load at 50 Hz 
F1 
700 
240 
24.6 
234 
234 
Rated load at 60 Hz 
F1 
-- 
264 
25.1 
238 
238 
Rated load at 50 Hz 
F1 
-- 
264 
24.9 
228 
228 
Rated load at 60 Hz 
Model DSA-20R-12 FEU 150204 
F1 
-- 
90 
24.6 
459 
459 
Rated load at 50 Hz 
F1 
-- 
90 
24.6 
470 
470 
Rated load at 60 Hz 
F1 
700 
100 
24.3 
409 
409 
Rated load at 50 Hz 
F1 
700 
100 
24.3 
433 
433 
Rated load at 60 Hz 
F1 
700 
240 
24.3 
244 
244 
Rated load at 50 Hz 
F1 
700 
240 
24.3 
230 
230 
Rated load at 60 Hz 
F1 
-- 
264 
24.7 
234 
234 
Rated load at 50 Hz 
F1 
-- 
264 
24.5 
224 
224 
Rated load at 60 Hz 
Note(s):-- 
 
2.1.1.5 
TABLE: max. V, A, VA test  
Voltage (rated) 
(V) 
Current (rated) 
(A) 
Voltage (max.) 
(V) 
Current (max.) 
(A) 
VA (max.) 
(VA) 
Model DSA-20R-12 FEU 150204 
15.0 
1.36 
14.9 
2.52 
26.2 
Model DSA-20R-12 FEU 102204 
10.2 
2.00 
10.2 
2.98 
22.8 
Note(s): 
Test voltage: 
240 V 
Test frequency: 60 Hz 
 
2.1.1.7 
TABLE: discharge test 
N/A 
Condition 
τ
 calculated 
(s) 
τ
 measured 
(s) 
t u→ 0V 
(s) 
Comments 
 
 
 
 
 
Page of 78