Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online
<12014238 001 >
Page 41 of 77
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
F1
--
264
22.2
218
218
Rated load at 50 Hz
F1
--
264
22.2
207
207
Rated load at 60 Hz
Model DSA-20R-12 FEU 102204
F1
--
90
25.3
476
476
Rated load at 50 Hz
F1
--
90
25.3
484
484
Rated load at 60 Hz
F1
700
100
24.9
417
417
Rated load at 50 Hz
F1
700
100
25.0
447
447
Rated load at 60 Hz
F1
700
240
24.6
246
246
Rated load at 50 Hz
F1
700
240
24.6
234
234
Rated load at 60 Hz
F1
--
264
25.1
238
238
Rated load at 50 Hz
F1
--
264
24.9
228
228
Rated load at 60 Hz
Model DSA-20R-12 FEU 150204
F1
--
90
24.6
459
459
Rated load at 50 Hz
F1
--
90
24.6
470
470
Rated load at 60 Hz
F1
700
100
24.3
409
409
Rated load at 50 Hz
F1
700
100
24.3
433
433
Rated load at 60 Hz
F1
700
240
24.3
244
244
Rated load at 50 Hz
F1
700
240
24.3
230
230
Rated load at 60 Hz
F1
--
264
24.7
234
234
Rated load at 50 Hz
F1
--
264
24.5
224
224
Rated load at 60 Hz
Note(s):--
2.1.1.5
TABLE: max. V, A, VA test
P
Voltage (rated)
(V)
Current (rated)
(A)
Voltage (max.)
(V)
Current (max.)
(A)
VA (max.)
(VA)
Model DSA-20R-12 FEU 150204
15.0
1.36
14.9
2.52
26.2
Model DSA-20R-12 FEU 102204
10.2
2.00
10.2
2.98
22.8
Note(s):
Test voltage:
240 V
Test frequency: 60 Hz
2.1.1.7
TABLE: discharge test
N/A
Condition
τ
calculated
(s)
τ
measured
(s)
t u→ 0V
(s)
Comments
Click on the first or last page to see other ON STAGE III IIIP (serv.man2) service manuals if exist.