ON STAGE III IIIP (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 44

Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online

 
 
<12014238 001 > 
 
 
Page 43 of 77 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
current (in A) 
≤8 
2.53 
apparent power (in VA) 
≤5*Uoc= 74.5 
26.8 
According to Table 2B (Opto-coupler primary short-circuited) 
current (in A) 
≤8 
0 (unit shut down) 
apparent power (in VA) 
≤5*Uoc= 74.5 
0 (unit shut down) 
According to Table 2B (Opto-coupler secondary open-circuited) 
current (in A) 
≤8 
2.50 
apparent power (in VA) 
≤5*Uoc= 74.5 
27.1 
According to Table 2B (Opto-coupler secondary short-circuited) 
current (in A) 
≤8 
2.80 
apparent power (in VA) 
≤5*Uoc= 74.5 
28.1 
Model DSA-20R-12 FEU 090180 
Uoc = 9.0 V (measured under no load conditions) 
According to Table 2B (normal condition) 
current (in A) 
≤8 
3.13 
power (in VA) 
≤5*Uoc=45.0 
22.5 
According to Table 2B (Opto-coupler primary open-circuited) 
current (in A) 
≤8 
2.94 
power (in VA) 
≤5*Uoc=45.0 
27.6 
According to Table 2B (Opto-coupler primary short-circuited) 
current (in A) 
≤8 
0 (unit shut down) 
power (in VA) 
≤5*Uoc=45.0 
0 (unit shut down) 
According to Table 2B (Opto-coupler secondary open-circuited) 
current (in A) 
≤8 
3.12 
power (in VA) 
≤5*Uoc=45.0 
26.3 
According to Table 2B (Opto-coupler secondary short-circuited) 
current (in A) 
≤8 
3.07 
power (in VA) 
≤5*Uoc=45.0 
29.3 
Note(s): -- 
 
2.6.3.3 
TABLE: ground continue test 
N/A 
Location 
Resistance measured (mΩ)  Comments 
 
 
 
 
 
 
 
 
 
Note(s): -- 