ON STAGE III IIIP (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 35

Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online

 
 
<12014238 001 > 
 
 
Page 34 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
S (IE): Apparatus which is fitted with a flexible 
cable or cord and is designed to be connected to 
a mains socket conforming to I.S. 411 by means 
of that flexible cable or cord and plug, shall be 
fitted with a 13 A plug in accordance with 
Statutory Instrument 525:1997 – National 
Standards Authority of Ireland (section 28) (13 A 
Plugs and Conversion Adaptors for Domestic 
Use) Regulations 1997. 
Direct plug-in equipment. 
N/A 
3.2.3 
C: Delete Note 1 and in Table 3A, delete the 
conduit sizes in parentheses. 
Deleted 
N/A 
3.2.5.1 
C: Replace 
"60245 IEC 53"  by  "H05 RR-F"; 
"60227 IEC 52"  by  "H03 VV-F or H03 VVH2-F"; 
"60227 IEC 53"  by  "H05 VV-F or H05 VVH2-F2". 
In Table 3B, replace the first four lines by the 
following: 
Up to and including 6  
 
0,75
1)
 
Over 6 up to and including 10  (0,75)
2) 
1,0 
Over 10 up to and including 16 (1,0)
3)
 
1,5 
In the Conditions applicable to Table 3B delete 
the words "in some countries" in condition 
1)
In Note 1, applicable to Table 3B, delete the 
second sentence. 
Replaced. 
N/A 
3.2.5.1 
S (GB): A power supply cord with conductor of 
1,25 mm
2
 is allowed for equipment with a rated 
current over 10 A and up to and including 13 A. 
Direct plug-in equipment. 
N/A 
3.3.4 
C: In table 3D, delete the fourth line: conductor 
sizes for 10 to 13 A, and replace with the 
following:
 
 
Deleted. 
N/A 
 
"Over 10 up to and including 16
 
1,5 to 2,5 
1,5 to 4" 
 
 
 
Delete the fifth line: conductor sizes for 13 to 
16 A. 
 
 
3.3.4 
S (GB): The range of conductor sizes of flexible 
cords to be accepted by terminals for equipment 
with a
 RATED CURRENT
 of over 10 A up to and 
including 13 A is: 
- 1,25 mm
2
 to 1,5 mm
2
 nominal cross-sectional 
area. 
Direct plug-in equipment. 
N/A 
4.3.6 
S (GB): The torque test is performed using a 
socket outlet complying with BS 1363 and the 
plug part of
 DIRECT PLUG
-
IN EQUIPMENT
 shall be 
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3, 
12.9, 12.11, 12.12, 12.16 and 12.17, except that 
the test of 12.17 is performed at not less than 
125 °C. 
See IEC 60950 and attached 
BS 1363 test report. 