Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online
<12014238 001 >
Page 34 of 77
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
S (IE): Apparatus which is fitted with a flexible
cable or cord and is designed to be connected to
a mains socket conforming to I.S. 411 by means
of that flexible cable or cord and plug, shall be
fitted with a 13 A plug in accordance with
Statutory Instrument 525:1997 – National
Standards Authority of Ireland (section 28) (13 A
Plugs and Conversion Adaptors for Domestic
Use) Regulations 1997.
cable or cord and is designed to be connected to
a mains socket conforming to I.S. 411 by means
of that flexible cable or cord and plug, shall be
fitted with a 13 A plug in accordance with
Statutory Instrument 525:1997 – National
Standards Authority of Ireland (section 28) (13 A
Plugs and Conversion Adaptors for Domestic
Use) Regulations 1997.
Direct plug-in equipment.
N/A
3.2.3
C: Delete Note 1 and in Table 3A, delete the
conduit sizes in parentheses.
conduit sizes in parentheses.
Deleted
N/A
3.2.5.1
C: Replace
"60245 IEC 53" by "H05 RR-F";
"60227 IEC 52" by "H03 VV-F or H03 VVH2-F";
"60227 IEC 53" by "H05 VV-F or H05 VVH2-F2".
"60227 IEC 52" by "H03 VV-F or H03 VVH2-F";
"60227 IEC 53" by "H05 VV-F or H05 VVH2-F2".
In Table 3B, replace the first four lines by the
following:
following:
Up to and including 6
0,75
1)
Over 6 up to and including 10 (0,75)
2)
1,0
Over 10 up to and including 16 (1,0)
3)
1,5
In the Conditions applicable to Table 3B delete
the words "in some countries" in condition
the words "in some countries" in condition
1)
.
In Note 1, applicable to Table 3B, delete the
second sentence.
second sentence.
Replaced.
N/A
3.2.5.1
S (GB): A power supply cord with conductor of
1,25 mm
1,25 mm
2
is allowed for equipment with a rated
current over 10 A and up to and including 13 A.
Direct plug-in equipment.
N/A
3.3.4
C: In table 3D, delete the fourth line: conductor
sizes for 10 to 13 A, and replace with the
following:
sizes for 10 to 13 A, and replace with the
following:
Deleted.
N/A
"Over 10 up to and including 16
1,5 to 2,5
1,5 to 4"
Delete the fifth line: conductor sizes for 13 to
16 A.
16 A.
3.3.4
S (GB): The range of conductor sizes of flexible
cords to be accepted by terminals for equipment
with a
cords to be accepted by terminals for equipment
with a
RATED CURRENT
of over 10 A up to and
including 13 A is:
- 1,25 mm
- 1,25 mm
2
to 1,5 mm
2
nominal cross-sectional
area.
Direct plug-in equipment.
N/A
4.3.6
S (GB): The torque test is performed using a
socket outlet complying with BS 1363 and the
plug part of
socket outlet complying with BS 1363 and the
plug part of
DIRECT PLUG
-
IN EQUIPMENT
shall be
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3,
12.9, 12.11, 12.12, 12.16 and 12.17, except that
the test of 12.17 is performed at not less than
125 °C.
12.9, 12.11, 12.12, 12.16 and 12.17, except that
the test of 12.17 is performed at not less than
125 °C.
See IEC 60950 and attached
BS 1363 test report.
BS 1363 test report.
P