ON STAGE III IIIP (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 31

Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online

 
 
<12014238 001 > 
 
 
Page 30 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
tag must in addition be provided with a diagram 
which shows the connection of the other 
conductors, or be provided with the following text: 
"For tilslutning af de øvrige ledere, se 
medfølgende instalationsvejledning." 
1.7.5 
S (DK): Socket-outlets for providing power to 
other equipment shall be in accordance with the 
Heavy Current Regulations, Section 107-2-D1, 
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, 
when used on Class I equipment. For stationary 
equipment the socket-outlet shall be in accor-
dance with Standard Sheet DK 1-1b or DK 1-5a. 
No socket-outlet. 
N/A 
1.7.5 
A (DK, Heavy Current Regulations): 
CLASS
 
II
 
EQUIPMENT
 shall not be fitted with socket-
outlets for providing power to other equipment. 
No socket outlet. 
N/A 
1.7.12 
A (DE, Gesetz über technische Arbeitsmittel 
(Gerätesicherheitsgesetz) [Law on technical 
labour equipment {Equipment safety law}], of 23
rd
 
October 1992, Article 3, 3
rd
 paragraph, 2
nd
 
sentence, together with the "Allgemeine 
Verwaltungsvorschrift zur Durchführung des 
Zweiten Abschnitts des Gerätesicherheits-
gesetzes" [General administrative regulation on 
the execution of the Second Section of the 
Equipment safety law], of 10
th
 January 1996, 
article 2, 4
th
 paragraph item 2): 
Directions for use with rules to prevent certain 
hazards for (among others) maintenance of the 
technical labour equipment, also for imported 
technical labour equipment shall be written in the 
German language. 
NOTE: Of this requirement, rules for use even only by service 
personnel are not exempted.  
"Operation instruction" provided 
in German language. 
1.7.15 
A (CH, Ordinance on environmentally hazardous 
substances SR 814.013): 
Annex 4.10 of SR 814.013 applies for batteries. 
No batteries. 
N/A 
 
A (DE, Regulation on protection against hazards 
by X-ray, of 8
th
 January 1987, Article 5 [Operation 
of X-ray emission source], clauses 1 to 4): 
a) A licence is required by those who operate an 
X-ray emission source. 
b) A licence in accordance with Cl. 1 is not 
required by those who operate an X-ray emission 
source on which the electron acceleration voltage 
does not exceed 20 kV if 
1) the local dose rate at a distance of 0,1 m from 
the surface does not exceed 1 µSv/h and 
2) it is adequately indicated on the X-ray emission 
source that 
i)  X-rays are generated and 
ii)  the electron acceleration voltage must not 
exceed the maximum value stipulated by 
No radiation. 
N/A 