IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
EU Group Differences [C],  
EU Special National Conditions [S], EU A-Deviations [A] 
(EN 60950-1:2001, Annex ZB and Annex ZC) 
General 
C: Delete all the "country" notes in the reference 
document according to the following list: 
1.1.5  
Note 2 
1.5.8 
Note 2 
1.6.1 
Note  
1.7.2 
Note 4 
1.7.12 
Note 2 
2.6 
Note 
2.2.3 
Note 
2.2.4 
Note 
2.3.2 
Note 2, 7, 8 
2.3.3 
Note 1, 2 
2.3.4 
Note 2,3  2.7.1 
Note 
2.10.3.1 Note 4 
3.2.1.1 
Note 
3.2.3 
Note 1, 2 
3.2.5.1  Note 2 
4.3.6 
Note 1,2  4.7.2.2  Note 
4.7.3.1  Note 2 
6.1.2.1 
Note 
6.1.2.2  Note 
6.2.2 
Note 
6.2.2.1 
Note 2 
6.2.2.2  Note 
Note 4 
7.1 
Note 
 
G2.1 
Note 1, 2 
Annex H  Note 2 
Deleted 
N/A 
1.2.4.1 
S (DK): Certain types of Class I appliances (see 
3.2.1.1) may be provided with a plug not 
establishing earthing conditions when inserted 
into Danish socket-outlets. 
Class II equipment. 
N/A 
1.5.1 
A (SE, Ordinance 1990:944 and  
CH, Ordinance on environmentally hazardous 
substances SR 814.013, Annex 3.2, Mercury): 
Add 
NOTE – Switches containing mercury such as 
thermostats, relays and level controllers are not allowed.
 
No switch. 
N/A 
1.5.8 
S (NO): Due to the IT power system used (see 
annex V, Fig. V.7), capacitors are required to be 
rated for the applicable line-to-line voltage 
(230 V). 
Class II equipment. 
N/A 
1.7.2 
S (FI, NO, SE): 
 CLASS I PLUGGABLE EQUIPMENT 
TYPE A  
intended for connection to other 
equipment or a network shall, if safety relies on 
connection to protective earth or if surge 
suppressors are connected between the network 
terminals and accessible parts, have a marking 
stating that the equipment must be connected to 
an earthed mains socket-outlet. 
The marking text in the applicable countries shall 
be as follows: 
Class II equipment. 
N/A 
 
FI: "Laite on liitettävä suojamaadoituskoskettimilla 
varustettuun pistorasiaan" 
Class II equipment. 
N/A 
 
NO: "Apparatet må tilkoples jordet stikkontakt" 
Class II equipment. 
N/A 
 
SE: "Apparaten skall anslutas till jordat uttag" 
Class II equipment. 
N/A 
 
A (DK, Heavy Current Regulations): Supply cords 
of class I equipment, which is delivered without a 
plug, must be provided with a visible tag with the 
following text: 
Vigtigt! 
Lederen med grøn/gul isolation må kun tilsluttes 
en klemme mærket 
 
 eller  
  
If essential for the safety of the equipment, the 
Class II equipment 
N/A 
Page of 78