IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
EU Group Differences [C],
EU Special National Conditions [S], EU A-Deviations [A]
(EN 60950-1:2001, Annex ZB and Annex ZC)
EU Special National Conditions [S], EU A-Deviations [A]
(EN 60950-1:2001, Annex ZB and Annex ZC)
P
General
C: Delete all the "country" notes in the reference
document according to the following list:
document according to the following list:
1.1.5
Note 2
1.5.8
Note 2
1.6.1
Note
1.7.2
Note 4
1.7.12
Note 2
2.6
Note
2.2.3
Note
2.2.4
Note
2.3.2
Note 2, 7, 8
2.3.3
Note 1, 2
2.3.4
Note 2,3 2.7.1
Note
2.10.3.1 Note 4
3.2.1.1
Note
3.2.3
Note 1, 2
3.2.5.1 Note 2
4.3.6
Note 1,2 4.7.2.2 Note
4.7.3.1 Note 2
6.1.2.1
Note
6.1.2.2 Note
6.2.2
Note
6.2.2.1
Note 2
6.2.2.2 Note
7
Note 4
7.1
Note
G2.1
Note 1, 2
Annex H Note 2
Deleted
N/A
1.2.4.1
S (DK): Certain types of Class I appliances (see
3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted
into Danish socket-outlets.
3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted
into Danish socket-outlets.
Class II equipment.
N/A
1.5.1
A (SE, Ordinance 1990:944 and
CH, Ordinance on environmentally hazardous
substances SR 814.013, Annex 3.2, Mercury):
Add
CH, Ordinance on environmentally hazardous
substances SR 814.013, Annex 3.2, Mercury):
Add
NOTE – Switches containing mercury such as
thermostats, relays and level controllers are not allowed.
No switch.
N/A
1.5.8
S (NO): Due to the IT power system used (see
annex V, Fig. V.7), capacitors are required to be
rated for the applicable line-to-line voltage
(230 V).
annex V, Fig. V.7), capacitors are required to be
rated for the applicable line-to-line voltage
(230 V).
Class II equipment.
N/A
1.7.2
S (FI, NO, SE):
CLASS I PLUGGABLE EQUIPMENT
TYPE A
intended for connection to other
equipment or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
terminals and accessible parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
connection to protective earth or if surge
suppressors are connected between the network
terminals and accessible parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
be as follows:
Class II equipment.
N/A
FI: "Laite on liitettävä suojamaadoituskoskettimilla
varustettuun pistorasiaan"
varustettuun pistorasiaan"
Class II equipment.
N/A
NO: "Apparatet må tilkoples jordet stikkontakt"
Class II equipment.
N/A
SE: "Apparaten skall anslutas till jordat uttag"
Class II equipment.
N/A
A (DK, Heavy Current Regulations): Supply cords
of class I equipment, which is delivered without a
plug, must be provided with a visible tag with the
following text:
of class I equipment, which is delivered without a
plug, must be provided with a visible tag with the
following text:
Vigtigt!
Lederen med grøn/gul isolation må kun tilsluttes
en klemme mærket
Lederen med grøn/gul isolation må kun tilsluttes
en klemme mærket
eller
If essential for the safety of the equipment, the
Class II equipment
N/A