IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
the manufacturer or importer. 
c) A licence in accordance with Cl. 1 is also not 
required by persons who operate an X-ray 
emission source on which the electron 
acceleration voltage exceeds 20 kV if 
1) the X-ray emission source has been granted a 
type approval and 
2) it is adequately indicated on the X-ray emission 
source that 
i)  X-rays are generated 
ii) the device stipulated by the manufacturer or 
importer guarantees that the maximum 
permissible local dose rate in accordance 
with the type approval is not exceeded and 
iii) the electron acceleration voltage must not 
exceed the maximum value stipulated by the 
manufacturer or importer. 
d) Furthermore, a licence in accordance with 
Cl. 1 is also not required by persons who operate 
X-ray emission sources on which the electron 
acceleration voltage does not exceed 30 kV if 
1) the X-rays are generated only by intrinsically 
safe CRTs complying with Enclosure III, No. 6, 
2) the values stipulated in accordance with 
Enclosure III, No. 6.2 are limited by technical 
measures and specified in the device and 
3) it is adequately indicated on the X-ray emission 
source that the X-rays generated are ade-
quately screened by the intrinsically safe CRT. 
2.2.4 
S (NO): Requirements according to this annex, 
1.7.2 and 6.1.2.1 apply. 
Not TNV 
N/A 
2.3.2 
S (NO): Requirements according to this annex, 
6.1.2.1 apply. 
Not TNV 
N/A 
2.3.3 and 
2.3.4 
S (NO): Requirements according to this annex, 
1.7.2 and 6.1.2.1 apply. 
Not TNV 
N/A 
2.6.3.3 
S (GB): The current rating of the circuit shall be 
taken as 13 A, not 16 A. 
Class II equipment 
N/A 
2.7.1 
C: Replace the subclause as follows: 
Basic requirements
 
To protect against excessive current, short-
circuits and earth faults in 
PRIMARY CIRCUITS
protective devices shall be included either as 
integral parts of the equipment or as parts of the 
building installation, subject to the following, a), b) 
and c): 
a) except as detailed in b) and c), protective 
devices necessary to comply with the 
requirements of 5.3 shall be included as parts of 
the equipment; 
Replaced. 