Read JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate online
Page 9 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
5.2
Earth terminal
Class II apparatus.
N/A
Hazardous live terminals
No hazardous live terminals.
N/A
Supply output terminals (other than mains)
No socket outlet for providing
power to other apparatus
power to other apparatus
N/A
5.3
Use of triangle with exclamation mark
Correct symbol applied:
- On name plate label, and
- In circuit diagram.
Further; no incorrect use of
this symbol is found.
- On name plate label, and
- In circuit diagram.
Further; no incorrect use of
this symbol is found.
P
5.4
Instructions for use
User information in the
following language: English.
See comments in Summary
of Testing.
following language: English.
See comments in Summary
of Testing.
P
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc.
dripping or splashing. Warning concerning objects
filled with liquid, etc.
The user manual includes
information about danger
concerning dripping or
adequate instructions supplied
splashing and objects filled
with liquids.
information about danger
concerning dripping or
adequate instructions supplied
splashing and objects filled
with liquids.
P
b) Hazardous live terminals, instructions for wiring
No hazardous live terminals
N/A
c) Instructions for replacing lithium battery
No battery.
N/A
d) Class I earth connection warning
Class II apparatus
N/A
e) Instructions for multimedia system connection
Not applicable
N/A
f) Special stability warning for attachment of the
apparatus to the floor/wall
apparatus to the floor/wall
No such equipment
N/A
g) Warning: battery exposure to heat
No battery
N/A
h) Warning: protective film on CRT face
No CRT
N/A
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
mains switch location, accessibility and markings
Plug is regarded as disconnect
device and is readily operable.
device and is readily operable.
P
c) Instructions for permanently connected equipment
Not permanent connected
equipment
equipment
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
disconnection from the mains
Information provided in user
manual.
manual.
P