Page 13 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
8.19.2 
Mains switch ON indication  
By indicator lamp. 
8.20 
Switch not fitted in the mains cord  
 
8.21 
Bridging components comply with clause 14  
No such components. 
N/A 
8.22 
Non-separable thin sheet material  
No non-separable thin sheet 
material. 
N/A 
 
Electric shock hazard under normal operating conditions 
 
9.1 
Testing on the outside 
P 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No voltage exceeding 
1000V ac or 1500V dc.  
N/A 
9.1.1.1 
a) Open circuit voltages  
Mains input voltage > 35 Vac,  
see below. 
 
 
b) Touch current measured from terminal devices 
using the network in annex D ………………: 
(see appended table 9.1.1.1)
 
 
c) Discharge not exceeding 45 μC  
No part or contact of a  
terminal with stored voltages 
between 60V - 15 kV. 
N/A 
 
d) Energy of discharge not exceeding 350 mJ  
No part or contact of a terminal 
with stored voltages exceeding 
15kV. 
N/A 
9.1.1.2 
Test with test finger and test probe  
No access to hazardous  
live parts 
9.1.2 
No hazardous live shafts of knobs, handles or levers 
No live shaft, handles or levers 
N/A 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
No opening on top side of the 
enclosure. 
N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
Does not reach hazardous  
live parts 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
Does not reach hazardous  
live parts 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
No preset controls 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s: 
48V after 2 s, 
(Tested voltage at 264V) 
Bleeder resistors provided. 
See clause 14.1 b)  
 
If C is not greater than 0,1 μF no test needed  
> 0.1 uF 
N/A 
Page of 126