Read JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate online
Page 12 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Reinforced insulation, two layers each of which meet
10.3
10.3
Thin sheet insulation used in
TF91 and TF92 transformer
between pri. and sec. winding.
(see appended table 14.3.3)
TF91 and TF92 transformer
between pri. and sec. winding.
(see appended table 14.3.3)
P
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Thin sheet insulation used in
TF91 and TF92 transformer
between pri. and iron core (ic).
(see appended table 14.3.3)
TF91 and TF92 transformer
between pri. and iron core (ic).
(see appended table 14.3.3)
P
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
No primary wiring
N/A
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
Single insulation, but safely
anchored.
anchored.
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
No primary wiring
N/A
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
Single insulation, but safely
anchored.
anchored.
N/A
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
No Primary wires used.
N/A
Vibration test carried out…………………………:
See 12.12
N/A
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
Adequately fastened.
P
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
Covers adequately
fastened with screws.
fastened with screws.
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
Wires safely anchored away
from parts with high
temperature.
from parts with high
temperature.
P
8.16
Only special supply equipment can be used
Not supplied by a special
supply apparatus.
supply apparatus.
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
No such winding wire
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
See below
P
8.19.1
Disconnect device
Mains plug is used as
disconnect devices.
disconnect devices.
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
No all-pole switch or circuit
breaker.
breaker.
N/A