Read JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate online
Page 8 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
3 General
requirements
Safety class of the apparatus ……………………:
Class II apparatus.
P
4
General test conditions
4.1.4
Ventilation instructions require the use of the test box
Tested in a wooden test box
according to standard specified.
according to standard specified.
N/A
5
Marking and instructions
Comprehensible and easily discernible
Marking provided on the outsid
e
of the apparatus including
bottom side (Mass: 4.1 kg).
e
of the apparatus including
bottom side (Mass: 4.1 kg).
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / sprit
P
5.1
a) Identification, maker …………………………..:
Trade mark:
P
b) Model number or type reference ……………..:
Model no.:
JBL® OnBeat Xtreme™.
See copy of marking plate.
P
c) Class II symbol if applicable …………………..:
Class II symbol is applied in
according to IEC 60417-5172
according to IEC 60417-5172
P
d) Nature of supply …………………………….....:
a.c. symbol is applied in
according to IEC 60417-5032.
according to IEC 60417-5032.
P
e) Rated supply voltage ...…………….……………:
100-240V~
P
f) Mains frequency if safety dependant....…….:
50/60Hz
P
g) Rated current or power consumption for
apparatus supplied by supply apparatus for general
use ………:
apparatus supplied by supply apparatus for general
use ………:
The apparatus is connection
to an a.c. mains supply.
to an a.c. mains supply.
N/A
Measured current or power consumption ………...:
N/A
Deviation % (max 10%) ………………………....:
N/A
h) Power consumption marking for apparatus other
than single phase …………………………..……….:
than single phase …………………………..……….:
The apparatus is connection
to an a.c. mains supply.
to an a.c. mains supply.
N/A
i) Rated current or power consumption for apparatus
intended for connection to an a.c. mains supply ……:
intended for connection to an a.c. mains supply ……:
35W
P
Measured current or power consumption…….....:
(see appended table 7.1)
P
Deviation % (max 10%) ………………………....:
Not exceed the marked value
P
Click on the first or last page to see other ON BEAT XTREME (serv.man8) service manuals if exist.