Page 11 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
8.5
Class I equipment
Class II equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
No such resistors
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
No such capacitors
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Class II equipment
P
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Double/Reinforced insulation
complies with requirements
specified in clause 10 and 13.
complies with requirements
specified in clause 10 and 13.
P
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
The apparatus has isolated
transformer complies with
clause 14.3.
transformer complies with
clause 14.3.
P
Basic insulation bridged by components complying
with 14.3.4.3.
with 14.3.4.3.
No such components
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
No such capacitors.
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
No such capacitors.
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
CY91, CY92, CY93 and CY94
capacitors, bridging reinforced
insulation in the apparatus.
capacitors, bridging reinforced
insulation in the apparatus.
P
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm):
No such components
N/A
Reinforced insulation > 0,4 mm (mm) …….:
a. Transformers bobbin.
ref.
ref.
14.3.
b. Optocouplers inner
insulation, ref. 14.11.
insulation, ref. 14.11.
.
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
Insulation in TF91 and
TF92 transformers.
TF92 transformers.
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A