Report No.: 171153
ATTACHMENT 6
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
13.3.1
General – loudspeaker voice coil
Add the following after the third paragraph:
CLEARANCES between a loudspeaker voice coil
and adjacent conductive parts shall be
disregarded.
and adjacent conductive parts shall be
disregarded.
Considered.
P
14.2
14.2.1
Capacitors and RC-units
(Y-Capacitors)
Add the following paragraph:
Add the following paragraph:
As an alternative an isolating capacitor complying
with applicable requirements of CSA C22.2 No 1,
shall be acceptable for bridging BASIC or
SUPPLEMENTARY INSULATION.
with applicable requirements of CSA C22.2 No 1,
shall be acceptable for bridging BASIC or
SUPPLEMENTARY INSULATION.
Considered.
P
14.2.2 (X-Capacitors)
Add the following paragraph:
As an alternative an across-line capacitor
complying with applicable requirements of CSA
C22.2 No 1, shall be acceptable.
complying with applicable requirements of CSA
C22.2 No 1, shall be acceptable.
60384-14 & CSA No. 1.
complied.
complied.
P
14.5.1
14.5.1.2
Thermal releases
Add the following paragraph:
As an alternative a THERMAL LINK complying
with CSA C22.2 No 209 shall be acceptable.
with CSA C22.2 No 209 shall be acceptable.
N/A
14.5.2
14.5.2.1
Fuse-links and fuse holders
Add the following paragraph:
As an alternative, a fuse-link complying with CSA
C22.2 No 248.14 shall be acceptable.
C22.2 No 248.14 shall be acceptable.
Fuses, IEC 60127.
P
14.5.2.4
Add the following paragraph:
As an alternative a Fuseholder Assembly
complying with CSA C22.2 No 39 shall be
acceptable.
complying with CSA C22.2 No 39 shall be
acceptable.
No fuseholder.
N/A
14.6.1 to
14.6.5
14.6.5
Switches:
Add the following to each of the Clauses:
As an alternative, a TV-Rated Switch complying
with CSA C22.2 No 1-98, Cl 9 shall be acceptable.
with CSA C22.2 No 1-98, Cl 9 shall be acceptable.
No switch.
N/A
14.11
Optocouplers
Add the following paragraph:
As an alternative, an optocoupler complying with
CSA C22.2 No. 1 shall be acceptable.
CSA C22.2 No. 1 shall be acceptable.
IEC60950 &
CSA No. 1.
complied.
P