ON BEAT MICRO (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 72

Read JBL ON BEAT MICRO (serv.man3) EMC - CB Certificate online

Issue Date: 
2012-10-23 
Page 22 of 41 
Report Reference # 
E204594-A37-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
connection to protective earthing - and to a cable 
distribution system using coaxial cable, may in 
some circumstances create a fire hazard.  
Connection to a cable distribution system has 
therefore to be provided through a device providing 
electrical isolation below a certain frequency range 
(galvanic isolator, see EN 60728-11)." 
NOTE: In Norway, due to regulation for installations 
of cable distribution systems, and in Sweden, a 
galvanic isolator shall provide electrical insulation 
below 5 MHz. The insulation shall withstand a 
dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz, 
for 1 min. 
Translation to Swedish: "Utrustning som är kopplad 
till skyddsjord via jordat vägguttag och/eller via 
annan utrustning och samtidigt är kopplad till kabel-
TV nät kan i vissa fall medfõra risk fõr brand. Fõr 
att undvika detta skall vid anslutning av 
utrustningen till kabel-TV nät galvanisk isolator 
finnas mellan utrustningen och kabel-TV nätet." 
           
2.3.2
 
 
            Requirements according to this annex, 
6.1.2.1 and 6.1.2.2 apply. 
           
 
             
           
N/A
 
2.10.5.13
 
 
            Requirements according to this annex, 
6.1.2.1 and 6.1.2.2 apply. 
           
 
             
           
N/A
 
5.1.7.1
 
 
            TOUCH CURRENT measurement results 
exceeding 3,5 mA r.m.s are permitted only for the 
following equipment: 
STATIONARY PLUGGABLE EQUIPMENT TYPE A 
that:  
(1) is intended to be used in a RESTRICTED 
ACCESS LOCATION where equipotential bonding 
has been applied, for example, in a 
telecommunication centre; and  
(2) has provision for a permanently connected 
PROTECTIVE EARTHING CONDUCTOR; and  
(3) is provided with instructions for the installation 
of that conductor by a SERVICE PERSON; 
- STATIONARY PLUGGABLE TYPE B 
- STATIONARY PERMANENTLY CONNECTED 
EQUIPMENT 
           
 
             
           
N/A
 