IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
It is permitted to bridge this insulation with an
optocoupler complying with 2.10.5.4 b).
It is permitted to bridge this insulation with a
capacitor complying with EN 132400:1994,
subclass Y2.
A capacitor classified Y3 according to EN 123400
[EN 60384-14:2005], may bridge this insulation
under the following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by EN
132400 [EN 60384-14], which in addition to the Y3
testing, is tested with an impulse test of 2,5 kV
defined in EN 60950-1:2006, 6.2.2.1;
- the additional testing shall be performed on all the
test specimens as described in EN 132400 [EN
60384-14];
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 132400 [EN
60384-14], in the sequence of tests as described in
EN 132400 [EN 60384-14.]
optocoupler complying with 2.10.5.4 b).
It is permitted to bridge this insulation with a
capacitor complying with EN 132400:1994,
subclass Y2.
A capacitor classified Y3 according to EN 123400
[EN 60384-14:2005], may bridge this insulation
under the following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by EN
132400 [EN 60384-14], which in addition to the Y3
testing, is tested with an impulse test of 2,5 kV
defined in EN 60950-1:2006, 6.2.2.1;
- the additional testing shall be performed on all the
test specimens as described in EN 132400 [EN
60384-14];
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 132400 [EN
60384-14], in the sequence of tests as described in
EN 132400 [EN 60384-14.]
6.1.2.2
The exclusions are applicable for
PERMANENTLY CONNECTED EQUIPMENT and
PLUGGABLE EQUIPMENT TYPE B and
equipment intended to be used in a RESTRICTED
ACCESS LOCATION where equipotential bonding
has been applied, e.g. in a telecommunication
centre, and which has provision for a permanently
connected PROTECTIVE EARTHING
CONDUCTOR and is provided with instructions for
the installation of that conductor by a SERVICE
PERSON.
N/A
7.2
Requirements according to this annex,
6.1.2.1 and 6.1.2.2 apply with the term
TELECOMMUNICATION NETWORK in 6.1.2
being replaced by the term CABLE DISTRIBUTION
SYSTEM.
N/A
7.3
Refer to EN 60728-11:2005 for installation
conditions
N/A