Read JBL ON BEAT MICRO (serv.man3) EMC - CB Certificate online
Issue Date:
2012-10-23
Page 21 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
Sweden - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009
1.2.13.14
Requirements according to this annex
1.7.2.1 and 7.3 apply.
N/A
1.5.7.1
Resistors bridging BASIC INSULATION in
CLASS I PLUGGABLE EQUIPMENT TYPE A must
comply with the requirements in 1.5.7.2. In
addition when a single resistor is used, the resistor
must withstand the resistor test in 1.5.7.2.
N/A
1.5.9.4
The third dashed sentence is applicable
only to equipment as defined by this annex, 6.1.2.2
N/A
1.7.2.1
CLASS I PLUGGABLE EQUIPMENT TYPE
A intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
accessible parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet. The marking text shall
be:"Apparaten skall anslutas till jordat uttag"
N/A
1.7.2.1
In Sweden, the screen of the cable
distribution system is normally not earthed at the
entrance of the building and there is normally no
equipotential bonding system within the building.
Therefore the protective earthing of the building
installation need to be isolated from the screen of a
cable distribution system. It is however accepted
to provide the insulation external to the equipment
by an adapter or an interconnection cable with
galvanic isolator, which may be provided by e.g. a
retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
"Equipment connected to the protective earthing of
the building installation through the mains
connection or through other equipment with a
N/A
Click on the first or last page to see other ON BEAT MICRO (serv.man3) service manuals if exist.