ON BEAT MICRO (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 71

Read JBL ON BEAT MICRO (serv.man3) EMC - CB Certificate online

Issue Date: 
2012-10-23 
Page 21 of 41 
Report Reference # 
E204594-A37-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
Sweden - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009 
 
 
1.2.13.14
 
 
            Requirements according to this annex 
1.7.2.1 and 7.3 apply. 
           
 
             
           
N/A
 
1.5.7.1
 
 
            Resistors bridging BASIC INSULATION in 
CLASS I PLUGGABLE EQUIPMENT TYPE A must 
comply with the requirements in 1.5.7.2.  In 
addition when a single resistor is used, the resistor 
must withstand the resistor test in 1.5.7.2. 
           
 
             
           
N/A
 
1.5.9.4
 
 
            The third dashed sentence is applicable 
only to equipment as defined by this annex, 6.1.2.2 
           
 
             
           
N/A
 
1.7.2.1
 
 
            CLASS I PLUGGABLE EQUIPMENT TYPE 
A intended for connection to other equipment or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network terminals and 
accessible parts, have a marking stating that the 
equipment must be connected to an earthed mains 
socket-outlet.  The marking text shall 
be:"Apparaten skall anslutas till jordat uttag" 
           
 
             
           
N/A
 
1.7.2.1
 
 
            In Sweden, the screen of the cable 
distribution system is normally not earthed at the 
entrance of the building and there is normally no 
equipotential bonding system within the building. 
Therefore the protective earthing of the building 
installation need to be isolated from the screen of a 
cable distribution system.  It is however accepted 
to provide the insulation external to the equipment 
by an adapter or an interconnection cable with 
galvanic isolator, which may be provided by e.g. a 
retailer. 
The user manual shall then have the following or 
similar information in Norwegian and Swedish 
language respectively, depending on in what 
country the equipment is intended to be used in: 
"Equipment connected to the protective earthing of 
the building installation through the mains 
connection or through other equipment with a 
 
             
           
N/A
 
Page of 99
Display