Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
"Equipment connected to the protective earthing of
the building installation through the mains
connection or through other equipment with a
connection to protective earthing - and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device providing
electrical isolation below a certain frequency range
(galvanic isolator, see EN 60728-11)."
NOTE: In Norway, due to regulation for installations
of cable distribution systems, and in Sweden, a
galvanic isolator shall provide electrical insulation
below 5 MHz. The insulation shall withstand a
dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.
Translation to Norwegian (the Swedish text will
also be accepted in Norway): “Utstyr som er koplet
til beskyttelsesjord via nettplugg og/eller via annet
jordtilkoplet utstyr - og er tilkoplet et kabel-TV nett,
kan forårsake brannfare. For å unngå dette skal det
ved tilkopling av utstyret til kabel-TV nettet
installeres en galvanisk isolator mellom utstyret og
kabel-TV nettet."
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
"Equipment connected to the protective earthing of
the building installation through the mains
connection or through other equipment with a
connection to protective earthing - and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device providing
electrical isolation below a certain frequency range
(galvanic isolator, see EN 60728-11)."
NOTE: In Norway, due to regulation for installations
of cable distribution systems, and in Sweden, a
galvanic isolator shall provide electrical insulation
below 5 MHz. The insulation shall withstand a
dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.
Translation to Norwegian (the Swedish text will
also be accepted in Norway): “Utstyr som er koplet
til beskyttelsesjord via nettplugg og/eller via annet
jordtilkoplet utstyr - og er tilkoplet et kabel-TV nett,
kan forårsake brannfare. For å unngå dette skal det
ved tilkopling av utstyret til kabel-TV nettet
installeres en galvanisk isolator mellom utstyret og
kabel-TV nettet."
2.2.4
Requirements according to this annex,
1.7.2.1, 6.1.2.1 and 6.1.2.2 apply.
Pass
2.3.2
Requirements according to this annex,
6.1.2.1 and 6.1.2.2 apply.
N/A
2.3.4
Requirements according to this annex,
1.7.2.1, 6.1.2.1 and 6.1.2.2 apply.
N/A
2.10.5.13
Requirements according to this annex,
6.1.2.1 and 6.1.2.2 apply.
N/A
Click on the first or last page to see other ON BEAT MICRO (serv.man3) service manuals if exist.