ON BEAT MICRO (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 68

Read JBL ON BEAT MICRO (serv.man3) EMC - CB Certificate online

Issue Date: 
2012-10-23 
Page 18 of 41 
Report Reference # 
E204594-A37-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
5.1.7.1
 
 
            TOUCH CURRENT measurement results 
exceeding 3,5 mA r.m.s are permitted only for the 
following equipment: 
- STATIONARY PLUGGABLE EQUIPMENT TYPE 
A that:  
(1) is intended to be used in a RESTRICTED 
ACCESS LOCATION where equipotential bonding 
has been applied, for example, in a 
telecommunication centre; and  
(2) has provision for a permanently connected 
PROTECTIVE EARTHING CONDUCTOR; and  
(3) is provided with instructions for the installation 
of that conductor by a SERVICE PERSON; 
- STATIONARY PLUGGABLE EQUIPMENT TYPE 

- STATIONARY PERMANENTLY CONNECTED 
EQUIPMENT 
           
 
             
           
N/A
 
6.1.2.1
 
 
            Add the following text between the first and 
second paragraph of the compliance clause: 
If this insulation is solid, including insulation 
forming part of a component, it shall at least consist 
of either 
- two layers of thin sheet material, each of which 
shall pass the electric strength test below, or 
- one layer having a distance through insulation of 
at least 0,4 mm, which shall pass the electric 
strength test below. 
 
Alternatively for components, there is no distance 
through insulation requirement for the insulation 
consisting of an insulating compound completely 
filling the casing, so that CLEARANCES and 
CREEPAGE DISTANCES do not exist, if the 
component passes the electric strength test in 
accordance with the compliance clause below and 
in addition 
- passes the tests and inspection criteria of 2.10.11 
with an electric strength test of 1,5 kV multiplied by 
1,6 (the electric strength test of 2.10.10 shall be 
performed using 1,5 kV), and 
- is subject to ROUTINE TESTING for electric 
strength during manufacturing, using a test voltage 
of 1,5 kV. 
 
 
             
           
N/A
 