ON BEAT MICRO (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 66

Read JBL ON BEAT MICRO (serv.man3) EMC - CB Certificate online

Issue Date: 
2012-10-23 
Page 16 of 41 
Report Reference # 
E204594-A37-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
Norway - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009 
 
 
1.2.13.14
 
 
            Requirements according to this annex 
1.7.2.1 and 7.3 apply. 
           
 
             
           
N/A
 
1.5.7.1
 
 
            Resistors bridging BASIC INSULATION in 
CLASS I PLUGGABLE EQUIPMENT TYPE A must 
comply with the requirements in 1.5.7.2.  In 
addition when a single resistor is used, the resistor 
must withstand the resistor test in 1.5.7.2. 
           
 
             
           
N/A
 
1.5.8
 
 
            Due to the IT power system used (see 
annex V, figure V.7), capacitors are required to be 
rated for the applicable line-to-line voltage (230 V). 
           
 
             
           
N/A
 
1.5.9.4
 
 
            The third dashed sentence is applicable 
only to equipment as defined in 6.1.2.2 of this 
annex. 
           
 
             
           
Pass
 
1.7.2.1
 
 
            CLASS I PLUGGABLE EQUIPMENT TYPE 
A intended for connection to other equipment or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network terminals and 
accessible parts, have a marking stating that the 
equipment must be connected to an earthed mains 
socket-outlet.  The marking text shall be: 
"Apparatet må tilkoples jordet stikkontakt" 
           
 
             
           
N/A
 
1.7.2.1
 
 
            In Norway, the screen of the cable 
distribution system is normally not earthed at the 
entrance of the building and there is normally no 
equipotential bonding system within the building. 
Therefore the protective earthing of the building 
installation need to be isolated from the screen of a 
cable distribution system.  It is however accepted 
to provide the insulation external to the equipment 
by an adapter or an interconnection cable with 
galvanic isolator, which may be provided by e.g. a 
retailer. 
 
             
           