JEMBE WIRELESS (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 19

Read JBL JEMBE WIRELESS (serv.man2) EMC - CB Certificate online

Report No. SF201200115                                                                                                        Page 19 of 32 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
19.5 
Glass  surfaces  (exc.laminated)  with  an  area 
exceeding  0,1 m
²  or  maximum  dimension 
> 450 mm, pass the test of 19.5.1 
 
19.6 
Wall or ceiling mountings adequate 
 
 
 
 
20 
RESISTANCE TO FIRE 
20.1 
Electrical components and mechanical parts 
 
a)  Exemption  for  components  contained  in  an 
enclosure  of  material  V-0  to  IEC  60695-11-10 
with openings not exceeding 1 mm in width 
 
 
b) Exemption for small components as defined in 
20.1 
 
20.1.1 
Electrical components meet the requirements of 
Clause 14 or 20.1.4 
 
20.1.2 
Insulation  of  internal  wiring  working  at  voltages 
> 4 Kv  or  leaving  an  internal  fire  enclosure,
  or 
located within the areas mentioned in Table 21,
 
not contributing to the spread of fire 
 
20.1.3 
Material  of  printed  circuit  boards  on  which  the 
available  power  exceeds  15 W  at  a  voltage 
between  50 V  and  400 V  (peak)  a.c.  or  d.c. 
meets V-1 or better to IEC60707, unless used in 
a fire enclosure 
Supply voltage: DC 12V 
No potential ignition source. 
 
Material  of  printed  circuit  boards  on  which  the 
available  power  exceeds  15 W  at  a  voltage 
>400 V  (peak)  a.c.  or  d.c.  meets  V-0  to 
IEC 60707 
 
20.1.4 
Components  and  parts  not  covered  by  20.1.1, 
20.1.2  and  20.1.3  (other  than  fire  enclosures) 
mounted  nearer  to  a  potential  ignition  source 
than  the  distances  in  Table 21  comply  with  the 
relevant flammability category in Table 21 
No  potential  ignition  source 
in the equipment. 
 
Components  and  parts  as  above  but  shielded 
from  a  potential  ignition  source,  with  the  barrier 
area in accordance with Table 21 and fig. 13 
 
 
Apparatus  with  voltages  >4kV  under  normal 
operating  conditions  and  distances  to  the 
enclosure  exceed  those  specified  Table  21, 
flammability  classification  HB40  or  better  is 
required for the enclosure. 
 
20.2 
Fire enclosure 
 
20.2.1 
Potential  ignition  sources  with  open  circuit 
voltage > 4 kV (peak) a.c. or d.c. contained in a 
fire enclosure to V-1 
 