Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
with IEC 60664-3 (basic insulation only)
N
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
No such parts
N
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
No such parts
N
14
COMPONENTS
14.1
Resistors
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistor
N
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N
b) Resistors separately approved ....................... : No
N
14.2
Capacitors and RC units
P
Capacitors separately approved
Yes
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. : Y1: CY1, CY2, CY3, CY4,
CY5, CY6
P
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. : X2: CX1, CX2
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ................... :
connected to the mains: tests for X2 ................... :
No such component
N
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better .............................................................. :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better .............................................................. :
EC16 metal case
N
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ................................... :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ................................... :
EC16 metal case
N
Shielded by a barrier to V-0 or metal .................. :
N
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N