Read JBL DSC 1000 EMC - CB Certificate online
Page 13 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
14.5
Protective devices
P
Protective devices used within their ratings
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
P
14.5.1.1
a) Thermal cut-outs separately approved
No such components
N
b) Thermal cut-outs tested as part of the
submission
submission
N
14.5.1.2
a) Thermal links separately approved
No such components
N
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices re-settable by soldering
N
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
FU1 approved.
P
14.5.2.2
Correct marking of fuse-links adjacent to holder .. : FU1: T3.15AL/250V
P
14.5.2.3
Not possible to connect fuses in parallel ............. :
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ........ :
replacing fuse-links without the use of a tool ........ :
P
14.5.3
PTC -S thermistors comply with IEC 60730-1
No such parts
N
PTC -S devices (15 W) category V-1 or better
N
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
and their position is correctly marked
N
14.6
Switches
P
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
V-0 compliance with annex G, G.1.1
Mains switch: ~250V,5A/80A
10E3
PTI 175
T85
Glow wire resistance 850
0
C
Inrush current <60A when
NTC is short circuit.
NTC is short circuit.
P
14.6.1 b)
Tested in the apparatus:
Separately approved
N
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N
Click on the first or last page to see other DSC 1000 service manuals if exist.