Read JBL DSC 1000 EMC - CB Certificate online
Page 9 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N
Class I protective earthing maintained
N
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
P
11.2.5
Temperature rise of windings
P
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
P
12
MECHANICAL STRENGTH
12.1.1
Bump test where mass >7 kg
4.6kg
N
12.1.2
Vibration test
Not carried out, no connection
which might impair safety can
become loosen
which might impair safety can
become loosen
P
12.1.3
Impact hammer test
0.5J
P
Steel ball test
2J
P
12.1.4
Drop test for portable apparatus where mass < 7
kg
kg
P
12.1.5
Thermoplastic enclosures strain relief test
70
o
C, 7h
P
12.2
Fixing of knobs, push buttons, keys and levers
P
12.3
Remote controls with hazardous live parts
N
12.4
Drawers (pull test 50 N, 10 s)
P
12.5
Antenna coaxial sockets providing isolation
N
12.6
Telescoping or rod antennas construction
N
12.6.1
Telescoping or rod antennas securement
N
13
CLEARANCE AND CREEPAGE DISTANCES
13.1
Clearances in accordance with 13.3
Between TR1 primary winding
and secondary winding
minimum 4.2mm required.
(458V peak)
and secondary winding
minimum 4.2mm required.
(458V peak)
Between TR2 primary winding
and secondary winding
minimum 4.3mm required.
(504V peak)
and secondary winding
minimum 4.3mm required.
(504V peak)
P