MX-3050N, MX-3060N, MX-3070N, MX-3550N, MX-3560N, MX-3570N, MX-4050N, MX-4060N, MX-4070N (serv.man77). CCE 1800 Rom Upgrade (1 2) for DSK ONLY MX-FR51U MX-FR52U Bulletin only - Sharp Copying Equipment Technical Bulletin (repair manual)

mx-3050n, mx-3060n, mx-3070n, mx-3550n, mx-3560n, mx-3570n, mx-4050n, mx-4060n, mx-4070n (serv.man77) technical bulletin
Model
MX-3050N MX-3060N MX-3070N MX-3550N MX-3560N MX-3570N MX-4050N MX-4060N MX-4070N (serv.man77)
Pages
10
Size
365.34 KB
Type
PDF
Document
Technical Bulletin
Brand
Device
Copying Equipment / CCE 1800 Rom Upgrade (1 2) for DSK ONLY MX-FR51U MX-FR52U Bulletin only
File
mx-3050n-mx-3060n-mx-3070n-mx-3550n-mx-3560n-mx-35.pdf
Date

Read Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man77) Technical Bulletin online

 
Technical Report
 
 
: MX-FR51U/FR52U 
 
No.  : CCE-1800 
 
Date: Sep. 6, 2017 
 
この資料に掲載されている表示価格は消税抜きです。 
 
 
SHARP CORPORATION 
Office Solutions Business Unit
 
ROM UPGRADE..... (1) ~ (2) 
 
 
Caution for firmware upgrade: Make sure to turn off the main power once. Then turn on the power 
and upgrade the firmware. 
 
- If the firmware update procedure is executed while MFP is still operating, the operation panel 
becomes black after the firmware upgrade and MFP may not be able to start up in some rare cases. 
 
 
- If upgrading from the version older than 0650Kc00, 0650Zc00 you won’t be able to 
restore original version. 
 
 
If "Google drive" is used with the version older than 0650Kc00, 0650Zc00 it will no longer 
be used after firmware upgrade. 
 
In that case, go into System Settings > Cloud Connect Settings and enable "Google drive" 
for usage. 
 
1. Model Name: 
MX-FR51U(Option for MX-3050N/3550N/4050N/5050N/6050N) 
 
MX-FR52U(Option for MX-3060N/3560N/4060N/3070N/3570N/4070N/5070N/6070N) 
 
2. Description: 
Upgrade of PCU-ROM
  ・・・(2) 
From September 2017 production 
Model 
ROM 
control 
No. 
BUNDLE 
ICU 
ASIC 
PCU 
SCU 
SPF 
MX-FR51U 
B01 
0651Kc00_ 
17080400 
0650K100 
0650Zc00 
0651Z100 
0500Z100 
MX-FR52U 
0651Zc00 _ 
17080400 
0650Z100 
0650Zc00 
0651Z100 
0500Z100 
0500Z100 
  Item of change  :See the separate page 
 
 
 
【Description】・・・(2) 
 
No. 
Item 
Description 
Model 
MX-3050N 
MX-3550N 
MX-4050N 
MX-3060N 
MX-3560N 
MX-4060N 
MX-3070N 
MX-3570N 
MX-4070N 
MX-5050N 
MX-6050N 
MX-5070N 
MX-6070N 
Main unit 
control 
Correction of the problem that FAN may continue rotating in Power Save 
Mode 
 
 
 
 
Main unit 
control 
Correction of the problem that the auto adjustment of fusing temperature 
is frequently caused when repeatedly performing the copies in 
color/B&W with the different sizes such as A3, B4, etc. 
 
The function not to display “Automatically adjusted” message of the 
fusing temperature has been added to Soft SW in order to enable the 
operation to read the next original during auto adjustment. 
Sim55-1 SW22-1 
0: Display (Default) 
1: Not display 
 
 
 
 
Main unit 
control 
Since there are some cases where H3 trouble has been detected in the 
region of CE Mark being applied.    Modification has been made to 
improve the trouble detection. 
 
 
 
 
 
 
Upgrade of ICU, ASIC, PCU, SCU and SPF-ROM
  ・・・(1) 
From Augsut 2017 production 
Model 
ROM 
control 
No. 
BUNDLE 
ICU 
ASIC 
PCU 
SCU 
SPF 
MX-LC17 
MX-FR51U 
B00 
0650Kc00_ 
17062300 
0650K100  0650Zc00  0650Z100  0500Z100 
0200Z100 
MX-FR52U 
0650Zc00 _ 
17062300 
0650Z100  0650Zc00  0650Z100  0500Z100  0500Z100 
  Item of change  :See the separate page 
 
 
 
○=applied 
 
 
【Description】・・・(1) 
 
No. 
Item 
Description 
Model 
MX-3050N 
MX-3550N 
MX-4050N 
MX-3060N 
MX-3560N 
MX-4060N 
MX-3070N 
MX-3570N 
MX-4070N 
MX-5050N 
MX-6050N 
MX-5070N 
MX-6070N 
Main unit 
control 
Implementation of Soft SW to print A5 size paper as A5R from Bypass tray. 
When this SW is enabled, the A5 size image output from Bypass tray is automatically 
output as A5R size. 
 
SIM55-3 SW39 Data 5 
0: Disabled (Default) 
1: Enabled 
 
*Following setting has to be turned ON to enable this feature: 
System Settings > Printer Settings > Condition settings > Enable Detected Paper Size 
in Bypass Tray: ON 
 
 
 
 
Main unit 
control 
Correction of operational failure: Following problem occurred when the MFP was used 
25 five days in a row (without turning off the power) 
- A message which indicates machine is not available for usage appeared. 
- The LCD turned dark. 
 
 
 
 
Main unit 
control 
Correction of slowing down the transmission speed after sending multiple jobs 
 
 
 
 
4
 
Main unit 
control 
Eliminating load on SSD 
The log data are written many times under the environment where the MFP switches 
to power save mode and recover from power save mode frequently. The transition time 
from 1W power save mode -> silent recovery -> power save mode has been changed 
from “1 min.” to “15 min.” to decrease the writing of log data to reduce load on SSD. 
 
 
 
 
5
 
Main unit 
control 
Correction of failure to change the current status of Machine Identification from “Input 
Tray Empty” 
 
 
 
 
6
 
Main unit 
control 
Correction of failure to recover from power save mode 
 
 
 
 
7
 
Main unit 
control 
Correction of failure to reflect the name of the registered paper type in the Tray 
Settings 
 
 
 
 
8
 
Main unit 
control 
Correction of failure to execute “Save User Count” 
 
 
 
 
9
 
Main unit 
control 
Correction of failure which tapping of “Contacts/Group Address” icon on Home screen 
rejected, displaying an error message “This function cannot be selected.”. 
 
 
 
 
10
 
Main unit 
control 
Correction of E7-03 error or failure to start-up MFP 
 
 
 
 
11
 
Main unit 
control 
Correction of high temperature offset on B4/B5 size paper with Plain Paper Weight 
Setting 80 g/m² - 150g g/m² 
 
Plain Paper Weight Settings 
System Settings > Common Settings > Device Control 
NA 
NA 
○ 
○ 
12
 
Main unit 
control 
Correction of L4-17~20   
The error due to toner waste buildup caused by the failure to detect waste toner box 
full has been fixed. 
 
 
 
 
13
 
Main unit 
control 
Change of heater lamp control 
This is to adjust to the fluorescent which flickers during fluctuation of voltage. 
 
 
 
 
14
 
Main unit 
control 
Remedy of overtoning and toner dispersion due to replenishment of excess amount of 
toner 
 
 
 
 
15
 
Main unit 
control 
Correction of C1-01/03/05/07 trouble during MC cleaning under HH environment 
NA 
NA 
○ 
○ 
 
 
○=applied 
 
 
 
【Description】・・・(1) 
 
No. 
Item 
Description 
Model 
MX-3050N 
MX-3550N 
MX-4050N 
MX-3060N 
MX-3560N 
MX-4060N 
MX-3070N 
MX-3570N 
MX-4070N 
MX-5050N 
MX-6050N 
MX-5070N 
MX-6070N 
16
 
Main unit 
control 
Correction of false detection of F2-22 (Discharge lamp trouble (K)) 
The trouble may occur while the job in monochrome mode (which tends to trigger the 
execution of process control for BK) is mainly running. 
NA 
NA 
 
 
17
 
Main unit 
control 
Correction of F2-65 trouble 
This trouble may occur if the MFP is runs out of toner during continuous run, failing to 
replenish the toner properly. 
NA 
NA 
○ 
○ 
18
 
Main unit 
control 
Correction of failure to recognize original 
The problem may occur if an OC cover is opened and closed too quickly after placing 
an original on the table, failing to detect original size. 
 
 
 
 
19
 
Main unit 
control 
Correction of machine lockup   
The lockup may occur while scanning non standard size originals (with 235 mm in 
width) on RSPF, displaying “Originals are being read”. 
 
 
 
 
20
 
Main unit 
control 
Implementation of selection whether to execute auto registration of user information in 
“User Control” -> “Default Settings” on main unit 
 
 
 
 
21
 
Main unit 
control 
Implementation of following features to erase cache information on authentication for 
cloud connection in User Control -> User List 
 
- Delete Your Information for External Connect 
- Delete All Information for External Connect 
 
 
 
 
22
 
Main unit 
control 
Addition of a mode which shows toner quantity in MIB until it turns “Empty” using 
values while toner quantity is “Low” 
SIM26-69 H (MIB TONER LOW INDIXATION) 
0: Retrieves information on toner quantity with value (Default) 
1. Retrieves “Low” status (-3) 
* “Toner Low” is not indicated with default condition. 
 
 
 
 
23
 
Main unit 
control 
Implementation of a Soft SW which turns on/off the confirmation message displayed 
when Blank Page Skip feature is enabled. 
SIM55-3 SW No.44   
Data 2 (Copy) 
Data 3 (Image Send) 
0: Display (Default) 
1: Do not display 
 
 
 
 
24
 
Main unit 
control 
Implementation of an error lamp setting in Device Settings with selections of “Not Use”, 
“Blink Only” and “Light & Blink” 
 
 
 
 
25
 
Main unit 
control 
Changing authentication setting for home directory during user registration from “Use 
Login Name And Password for User Authentication” to “Use Login Name for User 
Authentication” 
 
 
 
 
26
 
Main unit 
control 
Modification of behavior during Toner near end status as follows: 
- The alert on toner low is notified via E-RIC when an e-mail address is entered or 
“Toner Low” is selected on management web page. This won’t be affected whether 
SIM26-69 is set to A or C.   
SIM26-69 (Operating condition during toner near end) 
A: Whether to display a message to prompt preparation of toner 
C: Whether to display a message to notify toner near end 
 
 
 
 
27
 
Main unit 
control 
Correction of problem with touch panel which does not work in low temperature 
environment 
 
 
 
 
 
 
○=applied 
Page of 10
Display

Download Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man77) Technical Bulletin

Here you can read online and download Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man77) Technical Bulletin in PDF. MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man77) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man77) Copying Equipment. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.