CS680 - JBL Audio EMC - CB Certificate (repair manual). Page 16

Read JBL CS680 EMC - CB Certificate online

 
 
page 12 of 34 
Ref.No.:610604  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
14.5.2.3 
Not possible to connect fuses in parallel  ............... :  
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ......... :
Tools are required 
14.5.3 
PTC-S thermistors comply with IEC 60738 
 
N/A 
 
PTC-S devices (15 W) category FV 1 or better 
 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked 
 N/A 
14.6 
Switches 
     
(See appended table) 
14.6.1 Permanently 
connected 
equipment provided with 
an all-pole mains switch unless 5.4.2 is met 
 N/A 
14.6.2 
Manually operated mechanical switch (MOMS), 
required where power consumption > 15 W and/or 
peak voltage > 4 kV; MOMS required  ................... :
Yes  
 
Switch readily accessible and not in mains cord 
 
 
Exception for automatic switching 
 
N/A 
 
Exception for continuous operation 
 
N/A 
14.6.3 
Manually operated mechanical switch (MOMS): 
switch indication On position clearly discernible 
On P 
 
Indication by marking meets Cl. 5 
POWER 
 
Indication of the OFF position 
Off 
14.6.4 
Manually operated mechanical switch (MOMS) 
fitted, is there a Stand-by mode ............................. :
No N/A 
 
Stand-by mode clearly discernible ......................... :  
N/A 
 
Exception for low Stand-by current < 0.7 mA 
(peak) 
 N/A 
14.6.5 
Components bridging contacts of mains switches 
comply with 14.1 a) or 14.2.2 
Capacitor P 
14.6.6 
Manually operated mechanical switches (MOMS) 
separately approved to IEC 61058-1 
 P 
 
Manually operated mechanical switch (MOMS) 
tested as part of the equipment complies with 
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8 
and/or 14.6.9 and Annex G (G1.1) 
 N/A 
Page of 48
Display