MHS-FS1, MHS-FS1K, MHS-FS2, MHS-FS2K (serv.man3) - Sony Movie Service Manual (repair manual)

mhs-fs1, mhs-fs1k, mhs-fs2, mhs-fs2k (serv.man3) service manual
Model
MHS-FS1 MHS-FS1K MHS-FS2 MHS-FS2K (serv.man3)
Pages
8
Size
894.44 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / ADJUSTMENT MANUAL
File
mhs-fs1-mhs-fs1k-mhs-fs2-mhs-fs2k-sm3.pdf
Date

Read Sony MHS-FS1 / MHS-FS1K / MHS-FS2 / MHS-FS2K (serv.man3) Service Manual online

MHS-FS1/FS1K/FS2/FS2K_ADJ
Sony Corporation
Revision History
SECTION 5
ADJUSTMENT
ADJ
983456952.pdf
2011D29-1
© 2011.04
Published by Sony Techno Create Corporation
Ver. 1.1  2011.04
9-834-569-52
MHS-FS1/FS1K/FS2/FS2K
Link
•  PREPARATIONS
•  Adjustment Items When Replacing Lens 
Block (includes CMOS) and Main Board
•  List of Service Tools and Equipment
•  Keys and Functions
•  Connecting the Equipment
•  Setting the Adjustment Mode
•  CAMERA SECTION ADJUSTMENTS
•  AF Adjustment
•  AWB Adjustment
•  Bright Pixel Adjustment
•  M360 Adjustment
•  Set Language Destination
•  Check All above Adjustment Result 
(When Replacing Main Board only)
•  Remove adjustment FW 
(When Replacing Main Board only)
•  PRODUCT ID LIST
Ver.
Date
History
Contents
S.M. Rev.
issued
1.0
2011.04
Official Release
1.1
2011.04
Revised-1
(A1 11-005)
•  Addition of the Lens shading Adjustment.
  S.M. revised: Top cover, 
Page 5-2
5-3
5-4
5-5
5-6
5-7
5-8
MHS-FS1/FS1K/FS2/FS2K_ADJ
5-2
5. ADJUSTMENT
5-1.  PREPARATIONS
5-1-2. List of Service Tools and Equipment
5-1-3. Keys and Functions
Following are keys and functions used in adjustment. (Fig. 5-1-2)
Note1:
For the chart, search “J-6082-563-A” in the JIG & Software on ESI homepage, download the PDF file and print out it on the A4 size whitepaper.
Note2:
Print out the Near Focus-chart from the manual of MHS-FS3 in A4 size.
5-1-4. Connecting the Equipment
Connect the USB to USB charging adaptor and perform the adjustment during charging the built-in battery. (Fig.5-1-3)
Charge lamp may turn off during adjustment, but it does not affect the charging.
5-1-1. Adjustment Items When Replacing Lens Block (includes CMOS) and Main Board
Note:
Firmware
 for MHS-FS2/FS2K is written as default data in the internal memory in the main board for service. When replacing the MHS-FS1/FS1K main board, rewriting 
might be necessary with 
firmware 
for MHS-FS1/FS1K.
Contact your local Sony service Headquarter for the measures.
When replacing these parts, adjust the items indicated by “ z ” in the following table.
Adjustment
Replaced parts
Lens Block
(includes CMOS)
Main Board
AF Adjustment
z
z
AWB Adjustment
z
z
Bright Pixel Adjustment
z
z
M360 Adjustment
(MHS-FS1K/FS2K only)
z
z
Set Language Destination
z
J-1
J-3
J-5
J-4
J-6
J-2
Fig. 5-1-1
J-7
J-8
Small pattern box
PTB-1450
J-6082-557-A
Mini flange back jig
J-6082-719-A
or
Flange back
adjustment jig
J-6082-563-A
Camera table
J-6082-384-A
AC-U50A series
or
AC-U501AD
USB charging adaptor
360 video lens
(Accessory)
(MHS-FS1K/FS2K only)
USB extension cable
(A plug to A socket)
(Commercially available)
Ball head
(Tiltable angle: 90° max.)
(Commercially available)
J-9
Chart
(Note1)
or
Near Focus chart
(for MHS-FS3)
(Note2)
Light balance filter
LB140
J-6080-058-B
or
Filter for color
temperature correction
(C14)
J-6080-058-A
• MHS-FS1/FS1K
Menu button
ON/OFF (Power) button
Charge lamp
button (Key S1)
• MHS-FS2/FS2K
ON/OFF (Power) button
Charge lamp
button (Key S1)
Menu button
Fig. 5-1-2
MOVIE/ENTER button
Multi-selector buttons
MOVIE/ENTER
button
(Key OK)
button (Key Right)
button (Key Up)
button (Key Left)
button (Key Down)
Fig. 5-1-3
To USB connector
Ball head
(Commercially available)
USB extension cable
(A plug to A socket)
(Commercially available)
USB charging adaptor
(AC-U50A series or AC-U501AD)
To USB jack
Camera table
(J-6082-384-A)
Only for [5-2-3. Bright Pixel Adjustment]
The changed portions from
Ver.1.0 are shown in blue.
Ver.1.1 2011.04
MHS-FS1/FS1K/FS2/FS2K_ADJ
5-3
Pressing the MENU button, the adjustment is completed and the initial screen for the adjustments appears.
To continue the adjustment, perform the operations mentioned from the next page.
Pressing the MENU button after the Bright Pixel adjustment finished normally, the screen will return to 
the normal mode. Be sure to turn off the power of the camera once.
When all adjustments are completed, press the ON/OFF (Power) button to finish the adjustment operations.
5-1-5. Setting the Adjustment Mode
1)  Download the firmware file “FS1_[][][]ADJ.zip”, “FS1K_[][][]ADJ.zip”, “FS2_[][][]ADJ.zip”, “FS2K_[][][]ADJ.zip” from the ESI homepage.
 
Uncompress the  “FS1_[][][]ADJ.zip”, “FS1K_[][][]ADJ.zip”, “FS2_[][][]ADJ.zip”, “FS2K_[][][]ADJ.zip” , then confirm that it includes the 
following item.
•  SDV5092C.bin
 
Note:
  Since the file name “SDV5092C.bin” is used on the above four models, pay attention to the applicable model from mistake.
2)  Save the uncompressed file “SDV5092C.bin” in the root directory of the slot named “BLOGGIE_SW”.
 
Note:
  Saving it in other directories causes a malfunction of program.
3)  With the camera turned off.
4)  Disconnect the USB cable from PC.
5)  Connect the equipment to be used by referring to “5-1-4 Connecting the Equipment”.
6)  Press the MOVIE/ENTER button (Key OK) for about five seconds and release when the LCD display turns on.
7)  After a few seconds, the LCD display will turn on and then show the adjustment mode screen.
8)  After a few seconds, the adjustment mode screen appears. (Fig. 5-1-4)
Key Left: AWB Adjust
Key Down: Bright Pix Adjust
Key Right: M360 Adjust
Key OK: Set Lang and Check Result
Key Up: AF Adjust
Fig. 5-1-4
Ver.1.1 2011.04
MHS-FS1/FS1K/FS2/FS2K_ADJ
5-4
(2) Near Focus Adjustment
Note:  Perform the Near Focus Adjustment after the Far Focus Adjustment.
1)  Be sure to set 10 + 1cm distance between the chart and the tip of camera lens.
2)  Check that the center of chart meets the center of shot image screen.
Color temperature = 5000 ± 300K
Luminance: LV9 to 11
Be sure not to turn off the power during adjusting.
The adjustment finished normally.
Far OK OOO
Pls Key MENU Enter...
Near OK OOO
Fig. 5-2-5
The adjustment is complete.
The adjustment is finished abnormally.
Far OK OOO
Pls ReAdjust Near Focus
Near NG XXX
Fig. 5-2-6
Malfunction of Near Focus ad-
justment.
Adjustment order
Screen display
Fig. 5-2-4
Equipment required: Chart
Chart
10 + 1cm
Camera
Confirm the indication
on the screen.
Finished normally.
Finished abnormally.
Check that Far Focus Adjustment (Page 5-3) is finished normally.
Place the camera in front of the Chart. (Fig. 5-2-4)
on the screen. (Fig. 5-2-5)
In case of the adjustment is finished normally,
the adjustment completion indication appears
(Fig. 5-2-6)
In case of the adjustment is finished abnormally,
the following indication appears on the screen.
In this case, confirm the adjusting environment
and readjust.
Press the
button (Key S1), then AF Adjustment (Near Focus Adjustment) starts.
5-2. CAMERA SECTION ADJUSTMENTS
5-2-1. AF Adjustment
 
(1) Far Focus Adjustment
Note:
 
When using the Flange back adjustment jig, take care of the following points:
•  For the illumination, use a light source such as an incandescent lamp or inverter type fluorescent light free from flickering.
•  Do not make an adjustment in the environment where fluorescent lamp flickering occurs even if the illuminance can be ensured with the room illumination only.
Use an incandescent lamp or inverter type fluorescent light at a place free from the influence of room illumination.
1)  Install the Flange back adjustment jig so that the distance between 
it and the front of lens of camera is 3cm or less.
Note:  Take care not to hit the Flange back adjustment jig when extend-
ing the lens.
2)  Make the height of Flange back adjustment jig and the camera equal.
3)  Check that the center of chart meets the center of shot image screen. 
Color temperature = 5000 ± 300K
Luminance: LV9 to 11
Be sure not to turn off the power during adjusting.
The adjustment finished normally.
Fig. 5-2-2
Far focus adjust...
Big search...
base pos:xxx
Far OK OOO
Pls change to Near Focus
The adjustment is complete.
The adjustment is finished abnormally.
Fig. 5-2-3
Far focus adjust...
Big search...
base pos:xxx
Far NG XXX
Pls ReAdjust Far Focus
Malfunction of Far Focus adjust-
ment
Adjustment order
Screen display
Fig. 5-2-1
Equipment required: Flange back adjustment jig
Flange back adjustment jig
3cm or less
Camera
Check that the camera is on the adjustment mode.
Confirm the indication
on the screen.
Finished normally.
Finished abnormally.
∗ For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Place the camera in front of the Flange back adjustment jig. (Fig. 5-2-1)
Press the Multi-selector button “ v (Key Up)”.
Press the
button (Key S1), then AF Adjustment (Far Focus Adjustment) starts.
In case of the adjustment is finished normally,
the adjustment completion indication appears
on the screen. (Fig. 5-2-2)
The adjustment will proceed to “Near Focus
Adjustment”, do not execute any key operation.
the following indication appears on the screen.
In case of the adjustment is finished abnormally,
(Fig. 5-2-3)
In this case, confirm the adjusting environment
and readjust.
Ver.1.1 2011.04
Page of 8
Display

Download Sony MHS-FS1 / MHS-FS1K / MHS-FS2 / MHS-FS2K (serv.man3) Service Manual (Repair Manual)

Here you can read online and download Sony MHS-FS1 / MHS-FS1K / MHS-FS2 / MHS-FS2K (serv.man3) Service Manual in PDF. MHS-FS1 / MHS-FS1K / MHS-FS2 / MHS-FS2K (serv.man3) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sony MHS-FS1 / MHS-FS1K / MHS-FS2 / MHS-FS2K (serv.man3) Movie. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.