Read JBL CS680 EMC - CB Certificate online
page 11 of 34
Ref.No.:610604
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14.3.4.1
Class
ΙΙ transformers have adequate separation
between hazardous live windings and accessible
windings (double or reinforced insulation)
windings (double or reinforced insulation)
Prim.-sec: 9.2mm
P
Coil formers and partition walls
≥ 0.4 mm
1.3mm P
14.3.4.2
Class
Ι transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class
ΙΙ transformers have adequate insulation
between hazardous live windings and accessible
parts (double or reinforced insulation)
parts (double or reinforced insulation)
Prim.-iron core: 6.2mm
P
Coil formers and partition walls
≥ 0.4 mm
1.3mm P
14.3.5.2
Class
Ι transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N/A
Component meets category FV 1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
Protective devices used within their ratings
P
External clearance and creepage distances
appropriate for the voltage across the device when
opened
appropriate for the voltage across the device when
opened
P
14.5.1.1
a) Thermal cut-outs separately approved
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A
14.5.1.2
a) Thermal links separately approved
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices resettable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to
IEC 60127
IEC 60127
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : Fuse T1.25A L 250V
P
Click on the first or last page to see other CS680 service manuals if exist.