CS-UE7RKD, CS-UE9RKD, CS-UE12RKD, CS-UE18RKD, CU-UE7RKD, CU-UE9RKD, CU-UE12RKD, CU-UE18RKD - Panasonic Air Conditioner Service Manual (repair manual)

cs-ue7rkd, cs-ue9rkd, cs-ue12rkd, cs-ue18rkd, cu-ue7rkd, cu-ue9rkd, cu-ue12rkd, cu-ue18rkd service manual
Model
CS-UE7RKD CS-UE9RKD CS-UE12RKD CS-UE18RKD CU-UE7RKD CU-UE9RKD CU-UE12RKD CU-UE18RKD
Pages
127
Size
12.57 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-ue7rkd-cs-ue9rkd-cs-ue12rkd-cs-ue18rkd-cu-ue7rk.pdf
Date

Read Panasonic CS-UE7RKD / CS-UE9RKD / CS-UE12RKD / CS-UE18RKD / CU-UE7RKD / CU-UE9RKD / CU-UE12RKD / CU-UE18RKD Service Manual online

 
Order No: PAPAMY1502074CE 
 
 
 
Indoor Unit 
Outdoor Unit
CS-UE7RKD 
CS-UE9RKD 
CS-UE12RKD 
CS-UE18RKD 
 
 
CU-UE7RKD
CU-UE9RKD
CU-UE12RKD
CU-UE18RKD
Destination
Russia
Ukraine
Belarus
Kazakhstan
 
 
 
 
 
 
 
PRECAUTION OF LOW TEMPERATURE 
In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit.
 
 
WARNING 
This service information is designed for experienced repair technicians only and is not designed for use by the general public. 
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. 
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to 
service or repair the products dealt with in this service information by anyone else could result in serious injury or death. 
TABLE OF CONTENTS 
1.
 
Safety Precautions ............................................. 3
 
2.
 
Specifications ..................................................... 5
 
3.
 
Features ............................................................. 17
 
4.
 
Location of Controls and Components .......... 18
 
4.1
 
Indoor Unit .................................................. 18
 
4.2
 
Outdoor Unit ............................................... 18
 
4.3
 
Remote Control .......................................... 18
 
5.
 
Dimensions ....................................................... 19
 
5.1
 
Indoor Unit & Remote Control .................... 19
 
5.2
 
Outdoor Unit ............................................... 21
 
6.
 
Refrigeration Cycle Diagram ........................... 23
 
7.
 
Block Diagram .................................................. 24
 
7.1
 
CS-UE7RKD CU-UE7RKD 
CS-UE9RKD CU-UE9RKD ......................... 24
 
7.2
 
CS-UE12RKD CU-UE12RKD ..................... 25
 
7.3
 
CS-UE18RKD CU-UE18RKD ..................... 26
 
8.
 
Wiring Connection Diagram ............................ 27
 
8.1
 
Indoor Unit .................................................. 27
 
8.2
 
Outdoor Unit ............................................... 30
 
9.
 
Electronic Circuit Diagram .............................. 32
 
9.1
 
Indoor Unit .................................................. 32
 
9.2
 
Outdoor Unit ............................................... 35
 
10.
 
Printed Circuit Board ....................................... 37
 
10.1
 
Indoor Unit .................................................. 37
 
10.2
 
Outdoor Unit ............................................... 41
 
11.
 
Installation Instruction ..................................... 43
 
11.1
 
Select the Best Location ............................. 43
 
11.2
 
Indoor Unit .................................................. 44
 
11.3
 
Outdoor Unit ............................................... 49
 
12.
 
Installation Instruction ..................................... 52
 
12.1
 
Select the Best Location ............................. 52
 
12.2
 
Indoor Unit .................................................. 53
 
12.3
 
Outdoor Unit ............................................... 58
 
13.
 
Operation Control ............................................. 61
 
13.1
 
Basic Function ............................................ 61
 
13.2
 
Indoor Fan Motor Operation ....................... 62
 
13.3
 
Outdoor Fan Motor Operation .................... 63
 
13.4
 
Airflow Direction .......................................... 63
 
13.5
 
Timer Control .............................................. 65
 
13.6
 
Random Auto Restart Control .................... 66
 
13.7
 
Indication Panel .......................................... 66
 
13.8
 
Quiet Operation (Cooling Mode/Cooling Area 
of Dry Mode) ............................................... 66
 
13.9
 
Quiet Operation (Heating) .......................... 67
 
13.10
 
Powerful Mode Operation ........................... 67
 
14.
 
Protection Control ............................................ 68
 
14.1
 
Protection Control For All Operations ......... 68
 
14.2
 
Protection Control For Cooling & Soft Dry 
Operation .................................................... 70
 
14.3
 
Protection Control For Heating Operation .. 71
 
15.
 
Servicing Mode .................................................72
 
15.1
 
Auto OFF/ON Button ..................................72
 
15.2
 
Remote Control Button ...............................73
 
16.
 
Troubleshooting Guide ....................................74
 
16.1
 
Refrigeration Cycle System ........................74
 
16.2
 
Relationship Between The Condition Of The 
Air Conditioner And Pressure And Electric 
Current ........................................................75
 
16.3
 
Breakdown Self Diagnosis Function ...........76
 
16.4
 
Error Codes Table ......................................77
 
16.5
 
Self-diagnosis Method ................................79
 
17.
 
Disassembly and Assembly Instructions ... 108
 
17.1
 
Indoor Electronic Controllers, Cross Flow 
Fan and Indoor Fan Motor Removal 
Procedures .............................................. 108
 
17.2
 
Indoor Electronic Controllers, Cross Flow 
Fan and Indoor Fan Motor Removal 
Procedures .............................................. 113
 
17.3
 
Outdoor Electronic Controller Removal 
Procedure ........................................................... 117
 
18.
 
Technical Data ............................................... 119
 
18.1
 
Cool Mode Performance Data ................. 119
 
18.2
 
Heat Mode Performance Data ................. 121
 
19.
 
Service Data ................................................... 122
 
19.1
 
Cool Mode Outdoor Air Temperature 
Characteristic ........................................... 122
 
19.2
 
Heat Mode Outdoor Air Temperature 
Characteristic ........................................... 126
 
19.3
 
Piping Length Correction Factor .............. 130
 
20.
 
Exploded View and Replacement Parts List 132
 
20.1
 
Indoor Unit ............................................... 132
 
20.2
 
Outdoor Unit ............................................ 138
 
 
1. Safety Precautions 
 
Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. 
 
Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and 
main circuit for the model installed. 
 
The caution items stated here must be followed because these important contents are related to safety. The meaning of each 
indication used is as below. Incorrect installation or servicing due to ignoring of the instruction will cause harm or damage, 
and the seriousness is classified by the following indications. 
 
  
WARNING
 
This indication shows the possibility of causing death or serious injury. 
  
CAUTION
 
This indication shows the possibility of causing injury or damage to properties. 
 
 
The items to be followed are classified by the symbols: 
 
 
This symbol denotes item that is PROHIBITED from doing. 
 
 
Carry out test run to confirm that no abnormality occurs after the servicing. Then, explain to user the operation, care and 
maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference. 
 
  
WARNING
 
1. 
Do not modify the machine, part, material during repairing service. 
2. 
If wiring unit is supplied as repairing part, do not repair or connect the wire even only partial wire break. Exchange the whole wiring unit. 
3. 
Do not wrench the fasten terminal. Pull it out or insert it straightly. 
4. 
Engage dealer or specialist for installation and servicing. If installation of servicing done by the user is defective, it will cause water 
leakage, electrical shock or fire. 
5. 
Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electric shock or fire. 
6. 
Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water leakage, 
fire or electrical shock. 
7. 
Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly 
done, the set will drop and cause injury. 
8. 
For electrical work, follow the local national wiring standard, regulation and the installation instruction. An independent circuit and single 
outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 
9. 
This equipment is strongly recommended to install with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). 
Otherwise, it may cause electrical shock and fire in case equipment breakdown or insulation breakdown. 
10. 
Do not use joint cable for indoor / outdoor connection cable. Use the specified Indoor/Outdoor connection cable, refer to installation 
instruction CONNECT THE CABLE TO THE INDOOR UNIT and connect tightly for indoor / outdoor connection. Clamp the cable so that 
no external force will be acted on the terminal. If connecting or fixing is not perfect, it will cause heat up or fire at the connection. 
11. 
Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will 
cause heat-up or fire at the connection point of terminal, fire or electrical shock. 
12. 
When install or relocate air conditioner, do not let any substance other than the specified refrigerant, eg. air etc. mix into refrigeration 
cycle (piping). (Mixing of air etc. will cause abnormal high pressure in refrigeration cycle and result in explosion, injury etc.). 
13. 
Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit at veranda of high rise building, child may climb 
up to outdoor unit and cross over the handrail and causing accident. 
14. 
This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning rod and 
telephone. Otherwise, it may cause electric shock in case equipment breakdown or insulation breakdown. 
 
15.  Keep away from small children, the thin film may cling to nose and mouth and prevent breathing. 
 
16. 
Do not use unspecified cord, modified cord, joint cord or extension cord for power supply cord. Do not share the single outlet with 
other electrical appliances. Poor contact, poor insulation or over current will cause electrical shock or fire. 
 
17. 
Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the 
flare may break and cause refrigerant gas leakage. 
 
18. 
  For R410A model, use piping, flare nut and tools which is specified for R410A refrigerant. Using of existing (R22) piping, flare 
nut and tools may cause abnormally high pressure in the refrigerant cycle (piping), and possibly result in explosion and 
injury.  
  Thickness or copper pipes used with R410A must be more than 0.8 mm. Never use copper pipes thinner than 0.8 mm. 
  It is desirable that the amount of residual oil less than 40 mg/10 m. 
 
19. 
During installation, install the refrigerant piping properly before run the compressor. (Operation of compressor without fixing refrigeration 
piping and valves at opened condition will caused suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, 
injury etc). 
  
WARNING
 
20. 
During pump down operation, stop the compressor before remove the refrigeration piping. (Removal of compressor while compressor is 
operating and valves are opened will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.)
21. 
After completion of installation or service, confirm there is no leakage or refrigerant gas. It may generate toxic gas when the refrigerant  
contacts with fire. 
22.  Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when refrigerant contacts with fire. 
23.  Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury. 
 
24.  Must not use other parts except original parts described in catalog and manual. 
25.  Using of refrigerant other than the specified type may cause product damage, burst and injury etc. 
 
  
CAUTION
 
1. 
Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of 
the unit, it may cause fire. 
 
2. 
Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the 
furniture. 
3. 
Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may 
break and cause refrigerant gas leakage. 
4. 
Do not touch outdoor unit air inlet and aluminium fin. It may cause injury. 
 
5. 
Select an installation location which is easy for maintenance. 
6. 
Pb free solder has a higher melting point than standard solder; typically the melting point is 50°F – 70°F (30°C – 40°C) higher. 
Please use a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).
Pb free solder will tend to splash when heated too high (about 1100°F / 600°C). 
7. 
CS/CU-UE7/9/12RKD 
Power supply connection to the room air conditioner.  
Use power supply cord 3 × 1.5 mm² type designation 60245 IEC 57 or heavier cord. 
Connect the power supply cord of the air conditioner to the mains using one of the following method.  
Power supply point should be in easily accessible place for power disconnection in case of emergency. 
In some countries, permanent connection of this air conditioner to the power supply is prohibited. 
1)  Power supply connection to the receptacle using power plug. 
     Use an approved 15/16A power plug with earth pin for the connection to the socket. 
2)  Power supply connection to a circuit breaker for the permanent connection. 
     Use an approved 16A circuit breaker for the permanent connection. It must be a double pole switch with a minimum 3.0 mm contact  
     gap. 
8. 
CS/CU-UE18RKD 
Power supply connection to the room air conditioner.  
Use power supply cord 3 × 2.5 mm² type designation 60245 IEC 57 or heavier cord. 
Connect the power supply cord of the air conditioner to the mains using one of the following method.  
Power supply point should be in easily accessible place for power disconnection in case of emergency. 
In some countries, permanent connection of this air conditioner to the power supply is prohibited. 
1)  Power supply connection to the receptacle using power plug. 
     Use an approved 16A power plug with earth pin for the connection to the socket. 
2)  Power supply connection to a circuit breaker for the permanent connection. 
     Use an approved 16A circuit breaker for the permanent connection. It must be a double pole switch with a minimum 3.0 mm contact  
     gap. 
10. 
Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigerant parts. 
Take care of the liquid refrigerant, it may cause frostbite. 
 
11.  Installation or servicing work: It may need two people to carry out the installation or servicing work. 
12.  Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc. 
 
13.  Do not sit or step on the unit, you may fall down accidentally. 
 
14. 
Do not touch the sharp aluminium fins or edges of metal parts. 
If you are required to handle sharp parts during installation or servicing, please wear hand glove. 
Sharp parts may cause injury. 
 
 
 
 
 
 
 
Page of 127
Display

Download Panasonic CS-UE7RKD / CS-UE9RKD / CS-UE12RKD / CS-UE18RKD / CU-UE7RKD / CU-UE9RKD / CU-UE12RKD / CU-UE18RKD Service Manual (Repair Manual)

Here you can read online and download Panasonic CS-UE7RKD / CS-UE9RKD / CS-UE12RKD / CS-UE18RKD / CU-UE7RKD / CU-UE9RKD / CU-UE12RKD / CU-UE18RKD Service Manual in PDF. CS-UE7RKD / CS-UE9RKD / CS-UE12RKD / CS-UE18RKD / CU-UE7RKD / CU-UE9RKD / CU-UE12RKD / CU-UE18RKD service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic CS-UE7RKD / CS-UE9RKD / CS-UE12RKD / CS-UE18RKD / CU-UE7RKD / CU-UE9RKD / CU-UE12RKD / CU-UE18RKD Air Conditioner. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.