CINEMA 610 - JBL Audio EMC - CB Certificate (repair manual). Page 14

Read JBL CINEMA 610 EMC - CB Certificate online

 
 
 
 
Page 13 of 99 
 
 
 
Report No.: 17032770 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
13.4 
Creepage distances  
(see appended table 13.3 & 
13.4) 
 
Creepage distances greater than table 11 minimum 
values  
 
13.5 
Printed boards  
 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10  
 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only)  
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4  
 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8  
 
N/A 
 
Temperature cycle test and dielectric strength test  
 
N/A 
 
500V test for transformers, magnetic coupler and 
similar devices, if insulation is relied upon for safety 
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts 
not conductively connected to the mains, clearances 
and creepage distances as in table 12  
 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8  
Approved optocoupler 
– see 
appended table 14. 
 
14 
Components 
14.1 
Resistors  
 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts  
(see appended table) 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts  
 
N/A 
 
Resistors separately approved  ............................: 
Yes / No 
N/A 
14.2 
Capacitors and RC units  
 
 
Capacitors separately approved  : 
Yes 
14.2.1 
Y capacitors tested to IEC 60384-14:2005  ........... :  Y1-Capacitor. 
14.2.2 
X capacitors tested to IEC 60384-14:2005  ........... :  X2-Capacitor. 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  .................... : 
 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, where 
short-circuit current exceeds 0,2 A: compliance with 
IEC 60384-1, 4.38 category B or better  ................ : 
 
N/A 
Page of 108
Display

Click on the first or last page to see other CINEMA 610 service manuals if exist.