CINEMA 610 - JBL Audio EMC - CB Certificate (repair manual). Page 11

Read JBL CINEMA 610 EMC - CB Certificate online

 
 
 
 
Page 10 of 99 
 
 
 
Report No.: 17032770 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
8.19 
Disconnection from the mains 
Mains plug/coupler used 
8.19.1 
Disconnect device  
 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
 
N/A 
8.19.2 
Mains switch ON indication  
No such mains switch 
N/A 
8.20 
Switch not fitted in the mains cord  
Not fitted in the mains cord. 
8.21 
Bridging components comply with clause 14  
 
N/A 
8.22 
Non-separable thin sheet material  
 
N/A 
 
Electric shock hazard under normal operating conditions 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
< 1000 V 
N/A 
9.1.1.1 
a) Open circuit voltages  
See appended table for max. 
output of SPS. 
 
b) Touch current measured from terminal devices 
using the network in annex D ...............................: 
(see appended table 9.1.1) 
 
c) Discharge not exceeding 45 
μC  
< 45 
μC 
 
d) Energy of discharge not exceeding 350 mJ  
 
N/A 
9.1.1.2 
Test with test finger and test probe  
 
9.1.2 
No hazardous live shafts of knobs, handles or levers    
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  .................: 
Max. 28Vpeak measured after 
2 s (limit: 35Vpeak) 
 
If C is not greater than 0,1 
μF no test needed  
 
N/A 
9.1.7 
Resistance to external forces 
 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
 
N/A 
 
b) Test hook of fig. 4 for 10 s (20 N)  
 
N/A 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
100N 
9.2 
No hazard after removing a cover by hand  
No such removable cover. 
N/A 
 
10 
Insulation requirements 
Page of 108
Display