Page 14 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better .............................................:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better .............................................:
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ..................................................................:
metal ..................................................................:
Yes, metal cased capacitors.
P
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
Tested with appliance
N/A
14.3.1
Transformers and inductors marked with
manufacturer's name and type .............................:
manufacturer's name and type .............................:
(see appended table 14)
P
Transformers and inductors separately approved . :
No
N/A
14.3.2
General
P
Insulation material complies with clause 20.1.4
P
14.3.3
Constructional requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
P
14.3.3.2
Transformers meet the constructional requirements
P
14.3.4
Separation between windings
See Appendix 1
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation) ............................ :
between hazardous live parts and accessible parts
(double or reinforced insulation) ............................ :
P
Coil formers and partition walls > 0,4 mm
Min. 0.5mm
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic insulation
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
P
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
P
Coil formers and partition walls > 0,4 mm
Min. 0.5mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
N/A