Read JBL CINEMA 610 EMC - CB Certificate online
Page 8 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
8
Constructional requirements with regard to the protection against electric
shock
shock
P
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
No such material
N/A
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
No voltage setting device,
replaceable fuse-links or
drawers.
replaceable fuse-links or
drawers.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
P
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand
from parts rendered accessible following the
removal of a cover which can be removed by hand
P
8.5
Class I equipment
Class II apparatus
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
P
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
P
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
Transformers T1
P
Basic insulation bridged by components complying
with 14.3.4.3.
with 14.3.4.3.
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
Y Capacitors (CY1, CY2 and
CY4) used between primary
and secondary circuit.
CY4) used between primary
and secondary circuit.
P
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
Thickness of transformer
bobbin: 0.5mm
bobbin: 0.5mm
P
Reinforced insulation > 0,4 mm (mm) .................. :
See appended table 14 for
below information:
below information:
-
thickness of enclosure
-
optocoupler
P